4.2.1 CONNECTION OF EMERGENCY UNITS

Use a CAT. 5e SF/UTP cable for connecting the EMERG. socket (11) to the 'IN/OUT' sockets of the PMB132 remote emergency
units (up to 4). As an alternative, it is possible to connect up to 2 touch screen units TSB8500-V. The length of the link between
the card-cage and the last station must not exceed 1000 metres at most.

4.2.2 CONNECTION OF PAGING UNITS

Use a CAT. 5e SF/UTP cable for connecting the BROAD. socket (12) to the 'IN/OUT' sockets of the PMB106/112 paging units.
The length of the link between the card-cage and the last station must not exceed 1000 metres at most.
System manual
PAW5500-VES
CPU CIRCUIT
PMB132/12-V
+
24V
IN/OUT
IN/OUT
TSB8500-V
+
24V
IN/OUT
IN/OUT
CPU CIRCUIT
PMB112-G
PMB106-G
1,5W MAX
1,5W MAX
IN/OUT
IN/OUT
SENS.
IN/OUT
+
+
-
-
#1
11
PMB132-V
+
24V
IN/OUT
IN/OUT
#1
#2
#1
1,5W MAX
IN/OUT
SENS.
IN/OUT
IN/OUT
SENS.
+
-
#2
#3
EN
PMB132-V
+
24V
IN/OUT
IN/OUT
#4
MAX 4 units
TSB8500-V
+
24V
IN/OUT
IN/OUT
#2
MAX 2 units
1,5W MAX
IN/OUT
IN/OUT
SENS.
+
-
#16
MAX 16 units
PAW5500-VES Compact systems