Civco GUS G10VPL Operator's Manual

Wall-mounted disinfection soak station for transvaginal and transrectal ultrasound probes

Advertisement

G10VPL
Wall-Mounted
Disinfection Soak Station
For Transvaginal and Transrectal
Ultrasound Probes
Operator's Manual
Manufactured by:
CIVCO Medical Solutions
102 First Street South
Kalona, IA 52247 USA
Copyright © 2018 All Rights Reserved.
GUS® is a registered trademark of CIVCO Medical Solutions.
319.248.6757 / 800.445.6741
All other trademarks are property of their respective owners.
WWW.CIVCO.COM
Printed in the USA.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GUS G10VPL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Civco GUS G10VPL

  • Page 1 CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Copyright © 2018 All Rights Reserved. GUS® is a registered trademark of CIVCO Medical Solutions. 319.248.6757 / 800.445.6741 All other trademarks are property of their respective owners. WWW.CIVCO.COM Printed in the USA.
  • Page 2: Table Of Contents

    GUS Disinfection Soak Station™ Table of Contents Principle of Operation Safety Precautions Environmental Conditions Ventilation Requirements Supply Ratings Warning Symbols Signal Words Quick Troubleshoot Installation and Setup Items Included Wall Mounting Instructions Using High-Level Disinfectants with GUS Step 1: Probe Soaking Instructions Step 2: Filling the Containers Step 3: Ready for Use Repair and Modification...
  • Page 3: Principle Of Operation

    GUS Disinfection Soak Station™ Principle of Operation Your probe is suspended in the soaking container, preventing damage to the sensitive tip. Fumes are drawn into the unit away from the operator and into the filter. One of the containers is used for clean rinse water. This ensures that when the probe is removed from the unit for the final rinse, no high-level disinfectant will drip or off-gas.
  • Page 4: Warning Symbols

    4. Unscrew the fuse cover and remove the fuse. If the filament is damaged, replace it with a Type FSF 5 x 20mm 1 amp 250VAC. 5. If the unit is still not working, call CIVCO Medical Solutions at 1-800-445-6741. M0046_H...
  • Page 5: Installation And Setup

    GUS Disinfection Soak Station™ Installation and Setup Please check to ensure your new system arrived with the following parts. Items Included Four hollow wall anchors and screws for wall mounting the unit One ‘High-Level Disinfectant’ warning label Note: it is an OSHA requirement that containers holding high-level disinfectants be clearly marked as such.
  • Page 6 GUS Disinfection Soak Station™ 6. Using the enclosed Philips screwdriver, press the tip of the wall anchor through these two points and turn clockwise until the anchor is flush with the wall. 7. Screw two of the Philips screws into the anchors. Back off the screws approximately 1/8” from the wall and place the unit over the screws.
  • Page 7: Using High-Level Disinfectants With Gus

    Using High-Level Disinfectants with GUS Step 1: Probe Soaking Instructions CIVCO Medical Solution's new soak and rinse containers for the GUS G10VP and G14KA units are 17" tall. This allows your probes to be disinfected past the handle and strain relief.
  • Page 8: Step 2: Filling The Containers

    GUS Disinfection Soak Station™ Step 2: Filling the Containers 1. Plug in the unit and switch it on using the ON/OFF switch located on left side of unit. The red indicator will light when the unit is operating. 2. The G10VPL has two 17” containers: one for disinfectant and one for rinse water. 3.
  • Page 9: Repair And Modification

    4. For cleaning containers, see "Cleaning the System." Repair and Modification Do not modify or repair the unit without reviewing with CIVCO Medical Solutions; contact CIVCO Medical Solutions to purchase replacement filters and parts. Before attempting to perform routine maintenance on the unit, thoroughly review and understand this manual for complete familiarization with the unit and its operation.
  • Page 10: Filter Life

    GUS Disinfection Soak Station™ Filter Life GUS® has a patented filter that, in normal everyday use, will have a six-month life. Call CIVCO Medical Solutions at 1-800-445-6741 to purchase additional filters. Filter Replacement WARNING: Put cap on the tube containing your disinfectant. Turn the main power OFF and disconnect the power cord from the electrical outlet.
  • Page 11: Disposing Of Used High-Level Disinfectants

    Deactivation also protects the user from exposure to splashes and spills. CIVCO Medical Solutions manufactures Glute-Out®, a glycine-based neutralizer (part # 610-1099) which comes in a convenient single-use bottle. Glute-Out® is specifically for use with glutaraldehyde and OPA based disinfectants.
  • Page 12: Limited Warranty

    If the system is not working correctly or is defective, contact CIVCO Medical Solutions and we will repair or replace the device at our option during the warranty period.