Sony Net MD Walkman MZ-N1 Service Manual page 50

Sony portable minidisc recorder service manual
Table of Contents

Advertisement

MZ-N1
Pin No.
Pin Name
149
VDIOSC
150
OSCI
151
OSCO
152
VSIOSC
153
DAVDD
154
VREFL
155
AOUTL
156
AOUTR
157
VREFR
158
DAVSS
159
ASYO
160
ASYI
161
AVD1
162
BIAS
163
RFI
164
AVS1
165
PCO
166
FILI
167
FILO
168
CLTV
169
PEAK
170
BOTM
171
ABCD
172
FE
173
AUX1
174
VC
175
ADIO
176
ADRT
177
AVD2
178
AVS2
179
ADRB
180
SE
181
TE
182
DCHG
183
APC
184
CKRF
185
DTRF
186
XLRF
187
DVSS2
188
DVDD2
189
XTSL
190
DIN1
191 to
NC
193
194
DADT
50
I/O
Power supply terminal (for the OSC cell) (+2.2V)
I
System clock (45.1584MHz) input terminal
O
System clock (45.1584MHz) output terminal
I
Ground terminal (for the OSC cell)
Power supply terminal (for the built-in D/A converter) (+2.2V)
I
Reference voltage input terminal (for the built-in D/A converter L-CH)
O
Built-in D/A converter (L-CH) output terminal
O
Built-in D/A converter (R-CH) output terminal
I
Reference voltage input terminal (for the built-in D/A converter R-CH)
Ground terminal (for the built-in D/A converter)
O
Playback EFM duplex signal output terminal
I
Playback EFM comparison slice level input terminal
Power supply terminal (for the DSP asymmetry system analog) (+2.2V)
I
Bias current input terminal for the playback EFM comparison
I
Playback EFM the RF signal input from the RF amplifier
Ground terminal (for the DSP asymmetry system analog)
O
Phase comparison output terminal for the playback EFM system master PLL
I
Filter input terminal for the playback EFM system master PLL
O
Filter output terminal for the playback EFM system master PLL
I
Internal VCO control voltage input terminal for the playback EFM system master PLL
I
Peak hold signal input of the light amount signal (RF/ABCD) from the RF amplifier
I
Bottom hold signal input of the light amount signal (RF/ABCD) from the RF amplifier
I
Light amount signal (ABCD) input from the RF amplifier
I
Focus error signal input from the Focus error amplifier
I
Support signal (I
signal/temperature signal) input terminal (A/D input)
3
I
Middle point voltage (+1.1V) input terminal
O
Monitor output terminal of A/D converter input signal Not used
I
A/D converter the upper limit voltage input terminal (fixed at "H" in this set)
Power supply terminal (for the DSP servo analog system) (+2.2V)
Ground terminal (for the DSP servo analog system)
I
A/D converter the lower limit voltage input terminal (fixed at "L" in this set)
I
Servo signal monitor input terminal (A/D input) from the RF amplifier
I
Tracking error signal input from the Tracking error amplifier
Connecting terminal with the analog power supply of the low impedance (fixed at "H" in this set)
I
Error signal input for the laser automatic power control (fixed at "H" in this set)
O
Clock output terminal for the RF amplifier control Not used
O
Data output terminal for the RF amplifier control Not used
O
Latch signal output terminal for the RF amplifier control Not used
Ground terminal (for the DSP block)
Power supply terminal (for the DSP block) (+1.1V)
Input terminal for the frequency set up of the system clock
I
"L": 45.1584MHz, "H": 22.5792MHz (fixed at "L" in this set)
I
Input terminal of the record system digital audio signal
O
D/A converter PWM signal output terminal Not used
O
Audio data output terminal Not used
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mz-n1

Table of Contents