Radiant R1CR 24 Installation, Use And Maintenance Manual

Advertisement

Installation, Use
and Maintenance Manual
for model
R1CR 24
Condensing boiler
0476
R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX

Advertisement

Table of Contents
loading

Summary of Contents for Radiant R1CR 24

  • Page 1 Installation, Use and Maintenance Manual for model R1CR 24 Condensing boiler 0476 R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 2: Table Of Contents

    2.2. MAINTENANCE 2.2.7. GENERAL MAINTENANCE WARNINGS 2.2.8. TECHNICAL DATA 2.2.9. TECHNICAL ASSEMBLY 2.2.10. HYDRAULIC BOARD 2.2.11. WIRING DIAGRAM 2.2.12. ACCESSING THE BOILER 2.2.13. ACCESSING THE ELECTRONIC BOARD 2.2.14. SYSTEM EMPTYING R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 3 3.1.5. OPERATING MODE 3.1.6. INFORMATIONAL NOTE ON ANTI-FREEZE FUNCTION 3.1.7. SYSTEM FILLING 3.1.8. FAULT SIGNALLING CODES 3.1.9. ACTIVE FUNCTIONS SIGNALLING CODES 3.1.10. FAST H2O FUNCTION 3.1.11. MAINTENANCE 3.1.12. COVER CLEANING 3.1.13. DISPOSAL R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 4: Introduction

    › (See chap “chapter name”): this entry indicates another section in the Manual that you should refer to. › Device: this term is used referring to the boiler. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 5 PRODUCT CONFORMITY RADIANT BRUCIATORI spa declares that its gas boilers comply with the European Directives and with the requirements provided in the European standards below: › Eco-design Directive 2009/125 CE, R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 7: Installer Section

    1. INSTALLER SECTION 1. INSTALLER SECTION The installation operations described in this section should be performed only by qualified personnel, having the appropriate technical training in the field for the installation and maintenance of components of civil and industrial domestic hot water production and heating plants.
  • Page 8: Installation

    THIS BOILER HAS BEEN DESIGNED FOR OUTDOOR INSTALLATION IN A PARTIALLY PROTECTED R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 9: Reference Legislation

    1.1.3. REFERENCE LEGISLATION The installation must be realized according to the requirements of current legislation and in compliance with local technical regulations, according to the indications of the good technique. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 10: Unpacking

    › Turn the boiler at 90° holding it with your hand (fig. 1-B). › Lift the box (fig. 1-C) and remove the guards (fig. 1-D). fig. 1 R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 11: Overall Dimensions

    1. INSTALLATION 1.1.5. OVERALL DIMENSIONS 1.1.6. JIG 65 54 62 HEATING FLOW Ø 3/4 Ø 1/2 Ø 3/4 COLD Ø 1/2 HEATING RETURN Ø 3/4 R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 12: Positioning And Minimal Technical Spaces

    H - 1000 mm X - 60 mm fig.1 It is allowed an outdoor installation in a partially protected location (i.e. shelter, balcony) that respect the minimum measure indicated in figure 1200 mm R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 13 R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 14: Circulator Prevalence/Flow Diagram

    (see fig.1) so as to allow the condense to drain. fig.1 1.1.8. CIRCULATOR PREVALENCE/ FLOW DIAGRAM Wilo-Yonos PARA MSL 12/6B p/kPa Q/m³/ h Q/l/s Q/Igpm max. Q/m³/ h Appliance Loss R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 15: Hydraulic Connection

    The company assumes no liability for damage caused to persons or for failure to comply with these instructions. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 16: System Filling

    “M” (fig. 2) to make sure that the system pressure reaches 1.2 bar (fig. fig. 2 after performing this operation, make sure that the loading tap “R” (fig. 2) is properly closed. fig. 3 R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 17: Filling The Condensate Collection Siphon

    › Connect the dedicated flexible condensate draining tube “P” to a waste disposal system. The condensate can be drained directly in the sewerage system by inserting an easily serviceable siphon. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 18: Anti-Freeze Protection

    If the temperature goes below -10° centigrades, please fill the plant with anti-freeze liquid (CLEANPASS FLUIDO AG cod. 98716LA) and insert and electrical resistances kit (cod. 82259LP). R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 19: Gas Connection

    › the gas supply pressure falls within the values It is strictly forbidden the use of adaptors, indicated on the data plate. multiple plugs and/or extensions for the general power supply of the equipment from the electrical network. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 20: Optional Electrical Connections

    M0904 and then connect the two non-polarized conductors of the environment Thermostat or Remote control (see ‘TA’ or ‘CR’ fig. 2). After performing these operations, remount the crankcase and the front casing. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 21: Fume Exhaust Fittings

    › Make sure that the discharge tube doe not protrude inside the fumes exhaust duct, stop before it reaches the inner surface of the latter. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 22: Installation Modes

    The ducts must be certified for this specific use and for a temperature greater than 100 °C. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 23 The locations in which are installed gas devices must be vented so as to ensure the amount of air necessary for a regular combustion and for location ventilation. The natural air intake must take place directly through: R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 24: Types Of Fume Exhaust Systems

    Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: co-axial curve Ø60/100 at 90° = 1 m co-axial curve Ø60/100 at 45° = 0.6 m R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 25 Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: curve Ø80 at 90°= 1.5 m curve Ø80 at 45°= 1.2 m R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 26 Subsequent addition of a curve is similar to adding Ø100 a linear length of tube according to the indications below: Ø 60 curve Ø60/100 at 90° = 1 m curve Ø60/100 at 45° = 0.6 m R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 27: Support Centre Section

    1. SUPPORT CENTRE SECTION 2. SUPPORT CENTRE SECTION All operations described below relative to first start- up, maintenance and replacement should be performed only by qualified personnel and authorized by RADIANT BRUCIATORI S.p.A.
  • Page 28: First Start-Up

    Local and National Laws and Standards; › make sure that the heating system gate valves are open; › make sure that there is no intake of gaseous products within the system; R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 29: Boiler Commissioning

    › If the flame is missing, the board will repeat the start-up operations after post-ventilation (20 seconds). › You might have to repeat the start-up operation several times to release all the air inside the gas R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 30: Co2 Value Check And Calibration

    › After each adjustment variation on screw ‘1’ (fig. 2) of the gas flow adjuster you have to wait for the boiler to stabilize itself to the set value (about 30 seconds). R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 31: Accessing And Programming The Parameters

    'P00' to appear on the display, then release the buttons. Use the keys ‘ ’ and ‘ ’ of the heating circuit to select the parameter to be edited. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 32 ’ and ‘ ’ buttons of the domestic circuit to change the parameter value. Keep the ' ' button pressed until the parameter is displayed in order to confirm the modified value. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 33 2. FIRST START-UP To quit the parameters menu, press the ' button until 'OFF' is displayed. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 34: Miab3013 Parameters Table

    THE BOILER ACTIVITY IN CASE OF HIGH HEATING FLOW FOR FLOOR SYSTEMS TEMPERATURE. THE COMPANY ASSUMES NO LIABILITY FOR DAMAGE CAUSED TO PERSONS OR FOR FAILURE TO COMPLY WITH THESE INSTRUCTIONS. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 35 THROUGH THIS PARAMETER YOU CAN SET THE PUMP IN MULTIPLES OF 5 OPERATION DURATION ON THE DOMESTIC CIRCUIT, AFTER SECONDS THE TAP IS CLOSED. (PRE-SET AT 24 X 5 = 120 SECONDS) R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 36 IN HEATING MODE [SEE CHAPTER ‘HEAT CAPACITY DIAGRAM (KW) –ELECTRIC FAN FREQUENCY (HZ)’]. THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER P02) R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 37 SUCH DOMESTICH HOT WATER TREATMENT (AND INFORM THE USERS) TO AVOID UNFORSEEABLE DAMAGES TO PERSONS, ANIMALS AND PROPERTY. A THERMOSTATIC VALVE SHOULD BE INSTALLED AT THE DOMESTIC HOT WATER OUTLET TO AVOID ANY BURNS. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 38 (ONLY WITH MODULATING PUMP AND RETURN PROBE CONNECTED) IN PERCENTAGE THROUGH THIS PARAMETER YOU CAN SET THE MINIMUM SPEED VALUE OF THE MODULATING PUMP DURING A REQUEST TO OPERATE IN HEATING MODE. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 39 STARTING VALUE OF THE STORAGE TANK, COMPARED TO THE USER ADJUSTABLE D.H.W SETPOINT. TYPE OF VISUALIZATION 00 - 01 00 = HEATING CIRCUIT TEMPERATURE ONLY 01 = TEMPERATURE ACCORDING TO THE TYPE OF OPERATION (D.H.W. OR HEATING) R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 40: Electric Fan Frequency/Heat Capacity Diagram

    2. FIRST START-UP 2.1.6. ELECTRIC FAN FREQUENCY/HEAT CAPACITY DIAGRAM 95 110 125 140 155 170 185 200 215 230 245 260 275 FREQUENCY (Hz) GAS TYPE MINIMUM FREQUENCY MAXIMUM FREQUENCY R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 41: Maintenance

    › remove and clean the burner from oxidation; or neutralization devices for acid condensate. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 42 2. MAINTENANCE › check that the liquid flow is not obstructed and that there are no combustion gas refluxes inside the internal system. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 43: Technical Data

    .Domestic circuit Adjustable domestic temperature °C 35-60 Maximum pressure for domestic circuit Minimum pressure for domestic circuit Specific capacity in continuous service - Δt 30°C litres/min 11,5 Dimensional characteristics Width Depth R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 44 D.H.W Min. fan speed - G30 Fuel consumption - G30 kg/h 1,85 Nominal Supply pressure - G31 mbar Heating Max. fan speed - G31 D.H.W Max fan speed - G31 R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 45 At 30 % of rated heat output and low-temperature regime 96,3 At rated heat output of cogeneration space heater with CHP100+Sup0 At rated heat output of cogeneration space heater with CHP100+Sup100 Rated heat output Psup R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 46 (*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet. (**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet). R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 47: Technical Assembly

    11. SAFETY THERMOSTAT 12. HEATING PROBE 13. EXPANSION TANK 14. ELECTRIC FAN 15. WATER PRESSURE SWITCH 16. MODULATING PUMP 17. GAS VALVE 18. FLOW SWITCH 19. SAFETY VALVE 3 bar R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 48: Hydraulic Board

    DIVERTER VALVE DOMESTIC CIRCUIT PROBE FLOW SWITCH 10. AIR RELIEF VALVE 11. SAFETY THERMOSTAT 12. HEATING PROBE 13. AIR SUCTION TUBE 14. PROPORTIONAL VENTURI 15. CONDENSATE COLLECTION SIPHON 16. CIRCULATOR R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 49: Wiring Diagram

    L: LINE GI: YELLOW TRA:START-UP TRANSFORMER SS: DOMESTIC CIRCUIT PROBE N: NEUTRAL BI: WHITE TF: FUMES THERMOFUSE (102°C) EV: ELECTRIC FAN NE: BLACK GR. GREY VD: DIVERTER VALVE SRI: RETURN SENSOR R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 50: Accessing The Boiler

    › remove the fastening screws (2 - fig.1) placed on the front edge of the side panel; › grab the bottom of the panel and remove it by moving it sideways and then pulling it upwards (see fig. 1). R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 51: Accessing The Electronic Board

    › unscrew the two fastening screws 1 - fig. 1; › disengage the four hooks ‘2’ - fig. 1; fig. 1 › remove the crankcase pulling it upwards. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 52: System Emptying

    › close the main supply tap of the water supply network; › open all cold and hot water taps; › after completing all operations, close the discharge tap and all previously opened water taps. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 53: Fault Signalling Codes

    EQUAL TO THE ONE MEASURED BETWEEN PHASE AND GROUND, YOU HAVE TO INSTALL A PHASE-PHASE TRANSFORMER KIT (COD. 88021LA) SAFETY THERMOSTAT THERMOSTAT CABLE CHECK THE WIRING: AUTOMATIC. (95°C) DISCONNECTED; BROKEN THERMOSTAT. REPLACE IT. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 54 CHECK THE WIRING. PROBE CONNECTOR. RETURN PROBE BROKEN OR INCORRECTLY REPLACE IT; AUTOMATIC. CALIBRATED PROBE (RESISTANCE VALUE 10 KOHM AT 25 °C NTC); DISCONNECTED OR WET CHECK THE WIRING. PROBE CONNECTOR. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 55 SUPPLY VOLTAGE FALLS BACK WITHIN THE REQUESTED LIMITS). GENERAL INTERNAL INCORRECT SIGNAL IF THE MODULATION BOARD DOES NOT AUTOMATIC. BOARD ERROR RECOGNITION BY THE RESET THE ERROR AUTOMATICALLY, MODULATION BOARD REPLACE IT. MICRO-PROCESSOR. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 56: Active Functions Signalling Codes

    YOU CAN ACTIVATE/DEACTIVATED IT BY HOLDING SIMULTANEOUSLY AND FOR 7 SECONDS ‘ ’ THE RESET ‘ ’ AND OF THE HEATING CIRCUIT . THE “FAST H2O” FUNCTION GUARANTEES THE IMMEDIATE D.H.W SUPPLY AT THE REQUESTED TEMPERATURE. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 57: Gas Type Transformation

    ‘GAS TYPE SELECTION’ from the control panel (see chapters ‘MIAB2013 PARAMETERS TABLE’ and ‘ACCESSING AND PROGRAMMING THE PARAMETERS’); › adjust the CO2 combustion value as indicated in chapter ‘CO2 VALUE CHECK AND CALIBRATION’. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 59: User Section

    1. USER SECTION 3. USER SECTION The operations described in this section are addressed to all those who will use the machine. The machine must be used and accessed only by qualified operators that fully read and understood the User section, paying particular attention to the warnings.
  • Page 60: Use

    To validate the warranty, the boiler must create an air exchange that can quickly clean be started by a technical Support Centre authorized the location; by RADIANT no later than 30 days from the date of installation. › Close the gas valves; WARNING ›...
  • Page 61: Control Panel

    3. USE 3.1.2. CONTROL PANEL DOMESTIC WATER TEMPERATURE ADJUSTMENT KEYS OPERATING MODE SELECTION KEY: SUMMER / HEATING ONLY / WINTER / OFF RESET KEY: ANOMALY RESET HEATING TEMPERATURE ADJUSTMENT KEYS DISPLAY R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 62: Display Icons

    INDICATION OF PARAMETER NUMBER OR DISPLAYED INFO CODE. FLAME PRESENT SIGNALLING. ERROR DISPLAY THAT CAN BE RESET. OPERATION IN HEATING MODE ENABLED. fig. 1 PARAMETERS PROGRAMMING FUNCTION ACTIVE. OPERATION IN DOMESTIC MODE ENABLED. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 63: Info Menu Display Data

    LIST OF DISPLAYED DATA INFO CODE ICON DESCRIPTION DOMESTIC CIRCUIT PROBE TEMPERATURE HEATING CIRCUIT TEMPERATURE BURNER ACTUAL OUTPUT POWER (EXPRESSED IN PERCENTAGE) RETURN PROBE TEMPERATURE EXTERNAL PROBE TEMPERATURE FAN SPEED FREQUENCY R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 64: Start-Up

    OFF MODE burner; this is indicated by displaying the symbol ‘ ’ blinking. In this mode the boiler no longer meets the heating and domestic hot water demands, the anti-freeze, R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 65: Informational Note On Anti-Freeze Function

    › the boiler is not blocked. › Or leave the boiler in OFF operating mode keeping active the electrical and gas supplies so that the anti-freeze function may activate. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 66: System Filling

    2 minutes system relief cycle. Throughout this function the display will fig. 1 show the code “F33”. The boiler can work normally only after completing the operation. fig. 2 R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 67: Fault Signalling Codes

    IT, AS SOON AS THE ERROR CODE DISAPPEARS, THE BOILER WILL RESTART AUTOMATICALLY. IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE. REMOTE CONTROLLER INCOMPATIBLE CONTACT THE TECHNICAL SUPPORT CENTRE. SUPPLY VOLTAGE CONTACT THE TECHNICAL SUPPORT CENTRE. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 68 CUT OFF THE POWER SUPPLY FROM THE MAIN SWITCH AND THEN RESTORE IT, AS SOON AS THE ERROR CODE DISAPPEARS, THE BOILER WILL RESTART AUTOMATICALLY. IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 69: Active Functions Signalling Codes

    › the hot water is immediately supplied at the requested temperature. › unnecessary delays are avoided by increasing the comfort of the final user. › water wastes are limited waiting that the water reaches the right temperature. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 70: Maintenance

    (Waste Electrical and Electronic Equipment) shows that this product can not be dismantled as domestic waste. Proper dismantle of this product helps preventing potentially negative consequences on human health and environment. R1CR 24 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX...
  • Page 72 RADIANT BRUCIATORI s.p.a. Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: info@radiant • Internet: http://www.radiant.it...