Page 1
Installation, Use and Maintenance Manual for model R1KG 24 Premix condensing system boiler only heating 0476 R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
› (See chap “chapter name”): this entry indicates another section in the Manual that you should refer to. › Device: this term is used referring to the boiler. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 5
PRODUCT CONFORMITY RADIANT BRUCIATORI spa declares that its gas boilers comply with the European Directives and with the requirements provided in the European standards below: › Eco-design Directive 2009/125 CE, R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
1. INSTALLER SECTION 1. INSTALLER SECTION The installation operations described in this section should be performed only by qualified personnel, having the appropriate technical training in the field for the installation and maintenance of components of civil and industrial domestic hot water production and heating plants.
1.1.3. REFERENCE LEGISLATION The installation must be realized according to the requirements of current legislation and in compliance with local technical regulations, according to the indications of the good technique. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
› cut the fixing strip (see A-fig.1); › remove the cardboard box lifting it upwards (see B-fig.1); › push the boiler on one side and remove the pallet underneath (see C-fig.1). fig. 1 R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
1. INSTALLATION 1.1.8. CIRCULATOR PREVALENCE/FLOW DIAGRAM Wilo-Yonos PARA MSL 12/6B p/kPa Q/m³/ h Q/l/s Q/Igpm max. Q/m³/ h Appliance Loss R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
In order to avoid any scale or deposits on the primary exchanger, the hardness of the heating circuit infeed water should not exceed 25 °f. However, please check the characteristics of the water used and install suitable treating devices. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
2 green zone ‘ZV’ (fig. 4); after performing this operation, make sure that the loading tap “R” (fig. 2) is properly fig. 3 closed. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
› Connect the dedicated flexible condensate draining tube “P” to a waste disposal system. The condensate can be drained directly in the sewerage system by inserting an easily serviceable siphon. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
If the temperature goes below -10° centigrades, please fill the plant with anti-freeze liquid (CLEANPASS FLUIDO AG cod. 98716LA) and insert and electrical resistances kit (cod. 82259LP). R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
WARNING It is strictly forbidden the use of adaptors, multiple plugs and/or extensions for the general power supply of the equipment from the electrical network. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
· the blue cable to the terminal marked with “N”. · the brown cable to the terminal marked with “L”. After performing these operations, remount plate “A” and the front casing. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Ta- Ta contacts and then connect the two non- polarized conductors to the Ta-Ta contacts. After performing these operations, remount plate “A” and the front casing. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 21
GREY TAZ1: ENVIRONMENT THERMOSTAT AREA 1 ORANGE TAZ 2: ENVIRONMENT THERMOSTAT AREA 2 BLACK VZ1: AREA 1 VALVE BROWN VZ2: AREA 2 VALVE LIGHT BLUE VZR: REMOTE CONTROLLED AREA VALVE R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
› Make sure that the discharge tube doe not protrude inside the fumes exhaust duct, stop before it reaches the inner surface of the latter. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
The ducts must be certified for this specific use and for a temperature greater than 100 °C. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 24
The locations in which are installed gas devices must be vented so as to ensure the amount of air necessary for a regular combustion and for location ventilation. The natural air intake must take place directly through: R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: co-axial curve Ø60/100 at 90° = 1 m co-axial curve Ø60/100 at 45° = 0.6 m R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 26
Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: curve Ø80 at 90°= 1.5 m curve Ø80 at 45°= 1.2 m R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 27
Subsequent addition of a curve is similar to adding Ø100 a linear length of tube according to the indications below: Ø 60 curve Ø60/100 at 90° = 1 m curve Ø60/100 at 45° = 0.6 m R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
1. SUPPORT CENTRE SECTION 2. SUPPORT CENTER SECTION All operations described below relative to first start- up, maintenance and replacement should be performed only by qualified personnel and authorized by RADIANT BRUCIATORI S.p.A.
Local and National Laws and Standards; › make sure that the heating system gate valves are open; › make sure that there is no intake of gaseous products within the system; R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
› If the flame is missing, the board will repeat the start-up operations after post-ventilation (20 seconds). › You might have to repeat the start-up operation several times to release all the air inside the gas R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
› After each adjustment variation on screw ‘1’ (fig. 2) of the gas flow adjuster you have to wait for the boiler to stabilize itself to the set value (about 30 seconds). R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
’with the message ‘P00’, and release the keys ‘ ’ and ‘ ’. Use the keys ‘ ’ and ‘ ’ of the heating circuit to select the parameter to be edited. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 34
To exit the parameters menu, hold at the same time the keys ‘ ’ and ‘ ’ and wait for the symbol ‘ ’ to appear on the display. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
BOILER TYPE SELECTION 0 - 5 0 = ISTANTANEOUS R2K 1 = ISTANTANEOUS RKR 2 = ACCUMULATION 3 = ACCUMULATION COMFORT 4 = ISTANTANEOUS COMFORT - FAST H2O 5 = HEATING ONLY R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 36
MULTIPLES OF 5 SECONDS TIME FOR WHICH THE BURNER WILL BE TURNED OFF ONCE (PRE-SET AT 36 X 5 = 180 THE HEATING TEMPERATURE REACHED THE USER SET SECONDS) TEMPERATURE. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 37
IN HEATING MODE. [SEE CHAPTER ‘HEAT CAPACITY DIAGRAM (KW) – ELECTRIC FAN FREQUENCY (HZ)’]. THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER P02) R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 38
DOMESTICH HOT WATER TREATMENT (AND INFORM THE USERS) TO AVOID UNFORSEEABLE DAMAGES TO PERSONS, ANIMALS AND PROPERTY. A THERMOSTATIC VALVE SHOULD BE INSTALLED AT THE DOMESTIC HOT WATER OUTLET TO AVOID ANY BURNS. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 39
AND THE BOILER WILL TURN ON. EXAMPLE 2: WITH THE BOILER CLOCK SWITCH CLOSE, UPON THE REQUEST FOR DOMESTIC HOT WATER, THE FLOW SWITCH AND THE BOILER WILL NOT TURN ON. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 40
(ONLY WITH MODULATING PUMP AND RETURN PROBE PERCENTAGE CONNECTED) THROUGH THIS PARAMETER YOU CAN SET THE MAXIMUM SPEED VALUE OF THE MODULATING PUMP DURING A REQUEST TO OPERATE IN HEATING MODE. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 41
THE VALUE IS EXPRESSED IN (FOR STORAGE BOILERS ONLY) °C (PRE-SET AT 9°C) THROUGH THIS PARAMETER YOU CAN SET THE PRIORITY STARTING VALUE OF THE STORAGE TANK, COMPARED TO THE USER ADJUSTABLE D.H.W SETPOINT. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
2. FIRST START-UP 2.1.6. ELECTRIC FAN FREQUENCY/HEAT CAPACITY DIAGRAM FREQUENCY (Hz) GAS TYPE MINIMUM FREQUENCY MAXIMUM FREQUENCY R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
CALIBRATION”; › check that the liquid flow is not obstructed and that there are no combustion gas refluxes inside the › remove and clean the burner from oxidation; internal system. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Minimum operating pressure for heating circuit Capacity of the system expansion vessel litres Dimensional characteristics Width Depth Height Gross weight Water connections Flow Ø 3/4” Cold water Ø 1/2” Ø 3/4” R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 45
Fuel consumption - G30 kg/h 1,85 Nominal Supply pressure - G31 mbar Heating Max. fan speed - G31 Heating Min. fan speed - G31 Fuel consumption - G31 kg/h 1,83 R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 46
At rated heat output of cogeneration space heater with CHP100+Sup100 Rated heat output Psup Type of energy input Other items Standby heat loss P stby Ignition burner power consumption P R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 47
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet. (**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet). R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
11. HEATING PROBE 12. SAFETY THERMOSTAT 13. AIR SUCTION TUBE 14. START-UP TRANSFORMER 15. PROPORTIONAL VENTURI 16. SYSTEM FILLING TAP 17. WATER PRESSURE GAUGE 18. GAS VALVE 19. SYSTEM DRAINING TAP R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
TA: ENVIRONMENT THERMOSTAT AR: ORANGE VG: GAS VALVE SR: HEATING PROBE L: LINE GI: YELLOW TRA:START-UP TRANSFORMER EV: ELECTRIC FAN N: NEUTRAL BI: WHITE SRI: RETURN SENSOR NE: BLACK GR. GREY R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
‘1’ to position ‘2’ (see detail, C - fig. 2) › lift the panel by rotating it upwards; › unscrew both screws and remove the plate (see D, fig. 2). R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
› open the relief valves of the radiators starting fig. 1 from the one at the top and continuing downwards; › after draining out all water, close the relief valves of the radiators and the emptying tap. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
IF THE TENSION MEASURES BETWEEN PHASE-PHASE NEUTRAL AND GROUND IS ALMOST EQUAL TO THE ONE MEASURED BETWEEN PHASE AND GROUND, YOU HAVE TO INSTALL A PHASE-PHASE TRANSFORMER KIT (COD. 88021LA) R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 55
KOHM AT 25 °C NTC); DISCONNECTED OR WET CHECK THE WIRING. PROBE CONNECTOR. ELECTRIC FAN ELECTRIC FAN BOARD REPLACE IT; AUTOMATIC. BROKEN; ELECTRIC FAN BROKEN; REPLACE IT; FAULTY POWER SUPPLY REPLACE IT. CABLE. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 56
CHECK THE POWER SUPPLY AUTOMATIC. SUPPLY VOLTAGE OFF THE OPERATION RANGE ( 160 NETWORK (THE ERROR DEACTIVATES VOLTS). AUTOMATICALLY AS SOON AS THE SUPPLY VOLTAGE FALLS BACK WITHIN THE REQUESTED LIMITS). R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
ONLY AFTER THIS FUNCTION IS COMPLETED. IT CAN ALSO ACTIVATE DURING NORMAL BOILER OPERATION, IF THE WATER PRESSURE SWITCH CONFIRMATION IS MISSING, WHEN THE CONTACT IS RE-CLOSED, A 2 MINUTES RELEASE CYCLE WILL BE PERFORMED. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
‘GAS TYPE SELECTION’ from the control panel fig. 3 (see chapters ‘DIGITECH CS PARAMETERS TABLE’ and ‘ACCESSING AND PROGRAMMING THE PARAMETERS’); › adjust the CO2 combustion value as indicated in chapter ‘CO2 VALUE CHECK AND CALIBRATION’. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
1. USER SECTION 3. USER SECTION The operations described in this section are addressed to all those who will use the machine. The machine must be used and accessed only by qualified operators that fully read and understood the User section, paying particular attention to the warnings.
To validate the warranty, the boiler must create an air exchange that can quickly clean be started by a technical Support Centre authorized the location; by RADIANT no later than 30 days from the date of installation. › Close the gas valves; WARNING ›...
SWEEP FUNCTION ACTIVATION (HOLD FOR 7 SECONDS) VALUE OF THE PARAMETERS ADJUSTMENT KEY / HOLD THE KEYS AT THE SAME TIME FOR 5 SECONDS TO ACTIVATE DISPLAY BACK LIGHT FOR 10 MINUTES R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
MODULATING POWER LEVEL OF THE BOILER (fig.2) 11. ERROR DISPLAY THAT CAN BE RESET 12. OFF OPERATING MODE 13. ERROR DISPLAY THAT CAN NOT BE RESET 14. OPERATION IN HEATING MODE ENABLED R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
SOLAR BOILER TEMPERATURE (BOTTOM) [IF SOLAR BOARD INSTALLED] (SBSI) SOLAR BOILER TEMPERATURE (TOP) [IF SOLAR BOARD INSTALLED] (SBSS) SOLAR COLLECTOR PROBE TEMPERATURE 2 [IF SOLAR BOARD INSTALLED] (SCS2) EXTRA SOLAR BOILER TEMPERATURE [IF SOLAR BOARD INSTALLED] (SBS3) R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
’ to decrease the temperature. · press key ‘ ’ to increase the temperature. The heating temperature adjustment field ranges from 30 °C to 80 °C (25 °C – 45 °C for floor systems). R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
This function is available only if: › the boiler is powered; › the gas supply is open; › the pressure of the system is proper; › the boiler is not blocked. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Throughout this function the display will show the code “F33”. The boiler can work normally only after completing the operation. 1.5 bar 3 bar 1.2 bar 0.5 bar fig. 2 R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
CUT OFF THE POWER SUPPLY FROM THE MAIN SWITCH AND THEN RESTORE IT, AS SOON AS THE ERROR CODE DISAPPEARS, THE BOILER WILL RESTART AUTOMATICALLY. IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
Page 68
’ BUTTON ON THE CONTROL PANEL TO RESET THE FAULT, AS SOON AS THE ERROR CODE DISAPPEARS FROM THE DISPLAY, THE BOILER WILL START AUTOMATICALLY. SUPPLY VOLTAGE CONTACT THE TECHNICAL SUPPORT CENTRE. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
H E A T I N G WAIT UNTIL A N T I - F R E E Z E OPERATION IS COMPLETED FUNCTION ACTIVE SYSTEM WAIT UNTIL RELEASE CYCLE OPERATION IS COMPLETED IN PROGRESS R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...
(Waste Electrical and Electronic Equipment) shows that this product can not be dismantled as domestic waste. Proper dismantle of this product helps preventing potentially negative consequences on human health and environment. R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2...