MODELS:
Actuator Only: VC2, VC4, VC60, VC8 (See Table 1)
Bodies (Order Separately): VCZ..., (See 95C-10919)
Actuators
Model No.
Power
INTERNATIONAL MODEL [4]
VC2010zz00
24V~50Hz
VC2011zz00
24V~50Hz
VC2012zz00 [1]
24V~50Hz
VC2611zz00
24V~50Hz
VC4012zz00
200-240V~50-60Hz
VC4013zz00
200-240V~50-60Hz
VC4013zz11 [3] 200-240V~50-60Hz
VC4613zz00
200-240V~50-60Hz
VC6012zz00
200-240V~50-60Hz
VC6013zz00
200-240V~50-60Hz
VC6013zz11 [3] 200-240V~50-60Hz
VC6612zz00
200-240V~50-60Hz
VC6613zz00
200-240V~50-60Hz
VC8011zz00
24V~50Hz
VC8611zz00
24V~50Hz
NORTH AMERICA MODELS [4]
VC2114zz11 [3]
24V~60Hz
VC2714zz11 [3]
24V~60Hz
VC4011zz11 [3]
120V~60Hz
VC4013zz11 [3] 200-240V~50-60Hz
VC8111zz11 [3]
24V~60Hz
VC8114zz11 [3]
24V~60Hz
VC8711zz11 [3]
24V~60Hz
VC8714zz11 [3]
24V~60Hz
NOTE:
[1] with Snubber circuit
[2] Plenum rated with 1.5 meter cable
[3] Model number ending with "11" has conformal coated printed circuit
board for heating/cooling use.
[4] Some models are not available in all countries. Not all VC Actuator
modes are shown.
Table 1 - Actuator Model Identifiers
VC Valve Assembled dimensions for reference (Figure 1 & Table 2):
68 [2-3/4]
94 [3-3/4]
D
A
C
Figure 1 - Nominal dimensions in inches and millimetres
Control
Auxiliary
Special
Input
Switch
Features
SPDT
- -
Molex
SPDT
- -
Cable
SPDT
- -
Molex
SPDT
Yes
Cable
SPST
- -
Molex
SPST
- -
Cable
SPST
- -
Cable
SPST
Yes
Cable
SPDT
- -
Molex
SPDT
- -
Cable
SPDT
- -
Cable
SPDT
Yes
Molex
SPDT
Yes
Cable
SPST
- -
Cable
SPST
Yes
Cable
SPDT
- ­
Plenum[2]
SPDT
Yes
Plenum[2]
SPST
- -
Cable
SPST
- -
Cable
SPST
- -
Cable
SPST
- ­
Plenum[2]
SPST
Yes
Cable
SPST
Yes
Plenum[2]
94 [3-3/4]
90 [3-9/16]
B
B
AB
C
[4]
Pipe Fitting Sizes
1/2" BSPP (int.) [2]
1/2" BSPT (int.)
3/4" BSPP (int.)
3/4" BSPT (int.)
3/4" BSPP (ext.)
22mm Compression [3]
1" BSPP (int.)
1" BSPP (ext.)
1" BSPT (int.)
28mm Compression [3]
NORTH AMERICA STANDARD MODELS
3/8" FLARE [1]
1/2" SWEAT
1/2" FLARE [1]
1/2" INVERTED FLARE [1]
1/2" NPT (int.)
3/4" NPT (int.)
3/4" SWEAT
1" NPT (int.)
1" SWEAT
1-1/4" SWEAT
1-1/4" NPT (int.)
[1] No adapters
[2] Suitable for use as15 mm compression fitting
[3] Dimensions shown with nuts and olives installed
[4] Some models not available in all countries
Table 2 - VC Valve assembled dimensions
MANUAL OPENER
The manual opener can be manipulated only when in the up position.
The motorized valve can be opened by firmly pushing the red manual
lever down to midway and in. This holds the valve in the open
position. This "manual open" position may be used for filling, venting,
draining the system or for opening the valve in case of power failure.
The valve can be restored manually to the closed position by
depressing the red manual lever lightly and then pulling the lever out.
The valve and actuator will return to the automatic position when
power is restored.
NOTE: If the valve is powered open (the lever is down), it can not be
manually closed unless actuator is removed.
WHEN INSTALLING THIS PRODUCT:
1. Read these instructions carefully. Failure to follow them could
damage the product or cause a hazardous condition.
2. Check the ratings given in the instructions and on the product to
make sure the product is suitable for your application.
3. Installer must be a trained, experienced service technician.
4. Always conduct a thorough checkout when installation is com­
E
pleted.
5. While not necessary to remove the actuator from the body, it can
A
be removed for ease of installation. The actuator can be installed
in any position to suit the most convenient wiring mode.
6. An extra 1" (25 mm) head clearance is required to remove the
actuator.
CAUTION:
!
Disconnect power supply before connecting wiring to prevent
electrical shock and equipment damage.
On 24 V systems, never jumper the valve coil terminals, even
temporarily. This may damage the thermostat.
2
C
Dimensio n
mm Inches mm Inches mm Inches
98
3-7/8
111 4-3/8 136 5-11/32
94 3-11/16
113 4-7/16
112 4-7/16
94 3-11/16
95 3-11/17 114 4-7/17 137 5-11/33
94 3-11/16
113 4-7/16
116 4-9/16
98
3-7/8
3-1/2
89
111 4-3/8
98
3-7/8
94 3-11/16 113 4-7/16
110 4-5/16 118 4-5/8 142
D
E
130
5-1/8
140
5-1/2
136 5-11/32
136 5-11/32
147 5-13/16
136 5-11/32
130
5-1/8
136 5-11/32
130
5-1/8
132
5-3/16
136
5-11/32
5-5/8
INSTALLATION

Advertisement

loading

This manual is also suitable for:

Vc2010zz00Vc2011zz00Vc2012zz00Vc2611zz00Vc4012zz00Vc4013zz00 ... Show all