General Settings Screen Icon Layout
Figure 9: Smart Touch General Settings Screen Icon Layout
1.
Home Icon - Press this icon at any time to return to the Home Screen
2.
Back Icon - Press this icon to return to the previous screen
3.
Up Icon - Press the icon to increase the setting
4.
Down Icon - Press the icon to decrease the setting
5.
Save Icon - Press this icon save the desired setting changes
C
P
ONTROL
General Settings
To access the General Settings, go to Main Menu, Control Parameters, and the
General Settings.
1.
High Fan Speed Values for the upper fan-speed limit range from 35 to 95.
Set a higher number to increase the fan speed or a lower number to slow the
fan speed.
2.
Medium Fan Speed Values for the upper fan-speed limit range from 35 to
95. Set a higher number to increase the fan speed or a lower number to slow
the fan speed.
3.
Low Fan Speed Values for the lower fan-speed limit range from 32 to 85.
Set a higher number to increase the fan speed or a lower number to slow the
fan speed.
4.
Inside Temp Calibration This setting calibrates the ambient sensor within a range of ±10°F. Adjust this parameter to
display the correct room temperature reading. Note that setting increments are in °F even when the control is set to
display °C.
5.
Temperature Units (°F/°C/Auto) The default setting is °F. Select °C for
Celsius. (Celsius readings are displayed in tenths, for example 22.2°). Auto
corresponds to "automatic by line frequency", where 60 Hz automatically
sets the unit to Fahrenheit or °F, and 50 Hz automatically sets the unit to
Celsius or °C.
6.
Reversed Fan Speed in Heat Reverse Automatic Fan Speeds during
Heating lets you automatically reverse the fan speed during Heat Mode. This
improves heat output in cooler climates. The fan will speed up as the set
point is approached. Lowering the fan speed when the cabin is cold
increases head pressure and helps raise supply temperature. Increasing the
fan speed as the set point is approached also reduces unnecessary high-
pressure faults. The fan switches to low speed when the set point is satisfied and the compressor cycles off. The fan
can be programmed to operate the same as in cooling by selecting the Off option, which represents normal fan
operation during reverse-cycle heating.