Outlines And Dimensions - Mitsubishi Electric CITY MULTI Series Technical & Service Manual

Wall mounted
Hide thumbs Also See for CITY MULTI Series:
Table of Contents

Advertisement

4

OUTLINES AND DIMENSIONS

PKFY-P06NBMU-E2
PKFY-P06NBMU-E2R1
Detailed figure dwg (ABC)
(Knockout hole)
2-1/8(54)
31/32(24.4)
OCH516B
30-13/16(783)
32-3/32(815)
25-3/16(640)
Air intake
25-3/16(640)
27-3/8(695)
25-3/16(640) Drain pipe effective length
17-23/32(450)
20-25/32(520)
Knockout hole for
left piping
Knockout hole for
under piping
Knockout hole of
5/8(16)
3/32(2.5)
remocon wiring
3-19/32(91.5)
1-25/32(45)
Installation space
Min25/32(20)
Min55/64(22)
Installation plate balance point hole
3/16×1-3/8(4.5×35) 4 holes
Installation plate
6-1/4(159)
5-1/4(133)
4-13/16(122.5)
3-27/32(97.5)
3-11/32(85)
2-27/32(72.5)
2-3/8(60)
1-7/8(47.5)
7/8(22.5)
0
19/32(15)
3-17/32(90)
4-1/32(102.5)
4-7/8(124)
8-[5/32([4.3) holes
4-1/2(115)
4-3/16(106.7)
1/8(3)
Power supply
Transmission
Address board
Air intake
Air intake
2-3/8(60)
Air outlet
(Direction)
4-11/32(110)
Gas pipe
Liquid pipe
4-9/16(116)
Knockout hole of
right piping
Knockout hole for
remocon wiring
13/32(10)
1-11/32(34)
60mm or more for
left and left back piping.
Note.1 Use M10 or W3/8 screw for installation plate.
Note.2 Extension piping side.
Note.3 In case of connecting MA-remote controller, please
connect MA-remote controller cable (anaccssory) to the connector.
Refrigerant
piping
Min3-35/64(90)
Details of installation plate
Knock of hole
12-[1/8([2.8)holes
4-[11/32([9)holes
13
13
Unit : inch (mm)
Emergency operation
Emergency operation
Receiver
DEFROST/STAND BY lamp
Operation lamp
8-55/64(225)
Air intake
(Direction)
installation plate
Terminal block
Air intake
(Direction)
2-7/8(74.6)
Address board
Air outlet
Connection No.
Address board
Detailed
Address setting digit
Mode selection
*3 Address board is protected
With PL cover.
Remove the screw with driver
on the occasion of setting.
Terminal block Detailed
Power supply(208-230V)
Transmission(DC 24-30V)
MA-remote controller DC8.7-13V)
There is no MA-remote controller terminal block.
L1
L2
GR
M1
M2
Connection with MA-remote controller refers to Note.3
1/4F [6.35
Liquid pipe
1/2F [12.7
Gas pipe
[2-9/16([16) I.D
Drain pipe
6-5/8(168)
5-5/16(135)
4-29/32(125)
4-11/32(110)
3/16×1-15/32(4.5×37) 4 holes
3/16×1-9/16(4.5×40) 4 holes
1-3/8(35)
13/32(10)
0
1-3/32(27.5)
1-9/16(40)
2-3/32(53)
2-9/16(65)
3-7/16(87)
4-7/16(113)
5-1/32(128)
Piping hole[2-9/16([65)
87-[3/16([5.1)holes