Commissioning And Operation - NovoPress KE KELIT ACO103 BT Operating Manual

Hide thumbs Also See for KE KELIT ACO103 BT:
Table of Contents

Advertisement

ACO103 BT
Removing the battery (Fig. 2)
Push in (1) the two release buttons (A) and then remove the battery (2).
Inserting the battery (Fig. 3)
Slide the battery into the device as illustrated until it clicks into place.
Pos : 35 /RVT/Kurz bes chr eibung/Akku allgemei n/Akku Z ustands anzeig e/AC O103 @ 5\mod_1519654604495_18.doc x @ 35055 @ @ 1
Battery charge indicator (Fig. 2)
The 3 green LEDs (4) indicate the charge level of the battery. The number of LEDs lit up denotes the
battery charge. If the LED (2) is flashing, the battery is empty and no further travel is possible.
Pos : 36 /RVT/Kurz bes chr eibung/Ger ät + Akku/Info welc her Akku/12V: ACO103, AC O153 F unkschnittstelle @ 4\mod_1516803103870_18.doc x @ 33868 @ @ 1
Information!
The ACO103 BT press device must only be operated with 12 V lithium-ion
rechargeable batteries. The 12 V battery must only be used in the appropriate press
devices.
Pos : 37 /RVT/Kurz bes chr eibung/Ger ät + Akku/entl adener Akku/ACO102, AC O152, ACO/EC O202, ACO202XL, ACO401, AC O/ECO203 @ 0\mod_1382607696426_18.doc x @ 1532 @ @ 1
Feature of the press device when the battery is empty:
When a pressing operation begins, a check is made to determine whether the battery charge is
sufficient to complete the pressing operation. If this is not the case the device does not start. The
green LED (2) flashes.
If the green LED (2) flashes following a pressing operation, the pressing operation was carried out
correctly. The battery must be recharged prior to the next pressing operation.
Pos : 38 /RVT/Kurz bes chr eibung/Energies parmodus /Energiespar modus ACO203/EC O203 @ 4\mod_1506332076890_18.doc x @ 32143 @ 2 @ 1
7.6 Energy saving mode
If the press device is not used over an extended period, the device switches off. No LED is lit up any
longer. Press the start button (1) briefly to activate the press device.
Pos : 39 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/1a - Quetsc hgefahr Fing er ACO102, AC O152 @ 0\mod_1382615425260_18.doc x @ 1540 @ 12 @ 1
8

Commissioning and operation

8.1 Preparing the ACO103 BT
CAUTION!
Fingers risk being crushed if the device is operated without a press jaw
(Fig. 4)
If no press jaw is fitted, fingers could be placed in the at-risk zone. Fingers could be
crushed when the device is started.
Therefore:
Pos : 40 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/3 - Info-H altebolzen ACO/EC O202, ECO301, AC O/ECO203 @ 0\mod_1382617008258_18.doc x @ 1559 @ @ 1
Information!
The device will not start if the retaining pin (8) is incorrectly inserted. The green LED
flashes.
Pos : 41 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/4 - Info D auer betrieb ACO102, AC O152, ACO/EC O202, ACO202XL, EC O301, AF P/EFP202 @ 0\mod_1382617729764_18.doc x @ 1565 @ @ 1
Information!
The press device is not suitable for continuous operation. Following 30 minutes
of continuous operation, a short break of at least 15 minutes must be taken to
allow the device to cool down.
Pos : 42 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/5a - Ei ns etz en - AC O102, AC O152, @ 0\mod_1385644275462_18.doc x @ 1590 @ @ 1
Insert the press jaw into the press device as shown in Fig. 5 to 7.
Pos : 43 /RVT/Allgemeines /#### Seitenumbr uch #### @ 0\mod_1380200837280_0.doc x @ 885 @ @ 1
Do not operate the device without the press jaws.
Keep your fingers away from the at-risk zone.
9

Hide quick links:

Advertisement

Table of Contents
loading