2. OPERATION

2.1 Operating Condition
Indoor
32°C DB
Upper limit
Cooling
operation
Lower limit
18°C DB
Upper limit
27°C DB
Heating
operation
Lower limit
0°C DB
Note: DB - Dry Bulb
1. Optimum performance will be achieved within these operating temperatures.
2. When the unit operates above or below these conditions for a long time, system diagnostics may detect
a malfunction and the unit will not operate properly.
3. Room relative humidity - less than 80%. If the air conditioner operates outside this range, the surface of
the air conditioner may attract condensation. Please set the air flow louver to its maximum angle and set
HIGH fan mode.

2.2 Manual Operation

Manual operation is available to control the unit when your remote is unavailable.
ACCESS
Open the front panel by carefully
lifting both ends at the same time.
Once lifted sufficiently, a click is heard
and it becomes self-supporting.
OPERATE
Press the manual button repeatedly to change modes as follows;
a Once = AUTO mode [heat, cool or fan and auto fan speed].
b Twice=COOLING mode [ switches to AUTO mode after 30 minutes (mainly used
for testing purpose)].
c Three times = OFF.
COMPLETE
Close the panel by firmly tugging downwards on both ends until it returns to its
original position.
RESTORE
Using the remote controller will return the unit to normal operation.
07
Outdoor
43°C DB (Fixed speed models)
46°C DB (Inverter models)
52°C DB (High ambient models)
18°C DB(Fix speed models)
-10°C DB (Fix speed models with low ambient kit)
-15°C DB (inverter models)
24°C
DB
-10°C
DB (Fixed speed models)
-15°C
DB (Inverter models)
Manual Button

2.3 How It Works!

Basic Operation Modes:AUTO / COOL / DRY / HEAT* / FAN
[*]Model dependent
AUTO Mode
● In this setting the system will automatically change modes and fan speed to the
set temperature.
● In spring and autumn, closer temperature control may require COOL/HEAT mode
changes.
DRY Mode
In this mode, priority is given to dehumidifying the air. Low fan speed and
compressor cycling is used to achieve this and regulate room temperature.
SLEEP Mode
When selected, the set temperature will increase (cooling) or decrease (heating) by
1°C per hour for the first 2 hours. Thereafter it keeps this new temperature for 5
hours before switching off automatically. For some units, it keeps running with this new
temperature all the time until you adjust it.
This operation saves energy and improves night time comfort by synchronising with
the body's metabolism.
ECO Mode*
ECO mode can be activated at cooling mode for energy saving. When selected,
the unit will automatically regular the fan speed and compressor rotation. It
provides you the same comfort with minimum power consumption in 8 hours
running time.
Hints For Economical Operation
● Adjust the temperature to achieve moderate comfort levels.
● Excessively low or high temperatures waste energy.
● Improve performance by keeping windows and doors closed.
● Limit energy usage [run time] by using the TIMER function.
Use the timer
effectively
Please close
● Do not block air inlets or outlets. It will cause poor performance, increased running
costs and reduced product life.
● Inspect the air filters periodically, and clean them when needed.
cold
hot
Please clean
08

Advertisement