Terminal Block Connection - Huawei SUN2000 Series User Manual

Hide thumbs Also See for SUN2000 Series:
Table of Contents

Advertisement

SUN2000-(90KTL-100KTL) Series
User Manual
When laying out communications cables, separate them from power cables to avoid strong
signal interference sources.

5.6.2.1 Terminal Block Connection

Terminal Block Port Definitions
Figure 5-20
Figure 5-20 Terminal block
Table 5-3 Port definitions of the RS485 terminal block
No.
1
2
3
Recommended: DJYP2VP2-22 2x2x1 PC cable or communications cable with a
conductor cross-sectional area of 1 mm
RJ45 network port connection
Recommended: CAT 5E outdoor shielded network cable with an outer diameter less than
9 mm and internal resistance no greater than 1.5 ohms/10 m, with a shielded RJ45
connector
Select only one installation mode in practice. Terminal block connection is recommended.
shows an RS485 terminal block.
Port Definition
RS485A IN
RS485A OUT
RS485B IN
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2
and a cable outer diameter of 14–18 mm.
Description
RS485A, differential signal+
RS485A, differential signal+
RS485B, differential signal–
5 Electrical Connections
47