How To Use - Hitachi Koki metabo HPT RP 3608DA Safety Instructions And Instruction Manual

Cordless cleaner
Table of Contents

Advertisement

Available languages

Available languages

5.
Removing the battery (Fig. 10)
When removing the battery from the unit, press
the latches on both sides and slide the battery
upwards to pull it out.
Push
Latch
6.
Switch operation (Fig. 11)
During operation, suction power will change
each time you press the mode change-over
switch.
Mode display
lamp
Mode change-
over switch
Pressing the mode change-over switch switches
power as shown in Table 5.
Table 5
Display lamp
sequence
Air volume
57 (1.6)
cfm (m
/min)
3
Vacuum
degree
0.6 (42)
psi (hPa)
NOTE
When you switch ON the unit after switching it
OFF, the mode change-over switch will revert
to its state prior to being switched OFF.
The unit will revert to mode [2] when set at [3].
Pull out
Battery
Fig. 10
Fig. 11
85 (2.4)
124 (3.5)
1.2 (80)
2.9 (201)

HOW TO USE

CAUTION
Do not use the head top as a footstool or
do not sit on it. Otherwise the appliance
begins to move suddenly, causing an
injury.
NOTE
Handle the hose with care. Do not bend the
hose by force, or do not trample it, or do not
pull it to move the cleaner. Moreover, do not put
away the hose as it is bent. Otherwise troubles
such as its deformation may be caused.
1.
Connecting the hose (Fig. 12)
Press the attached hose into the suction
opening of the tank until it clicks and connect
it. When removing the hose, pull out the
hose while pushing the button of the suction
opening.
Push
Suction opening
Button
2.
Attaching the fi lter
WARNING
Be sure to turn off the vacuum switch and
disconnect the battery.
Be sure to attach the fi lter. (cloth fi lter or fi lter for
dusts) Otherwise the motor will be damaged.
When you collect fi ne dusts, such as siding
powder and stone powder, use the optional
paper fi lter.
Since it is a fi lter for dry and wet suction, do not
remove it when you suck up liquids, such as
water.
NOTE
If the fi lter is wet, leave it to dry out of direct
sunlight. Using the fi lter when wet will
conspicuously reduce the suction power.
(1)
Remove the two clamps, use the handles to
draw up the head and remove it from the tank.
(Fig. 13)
English
Pull out
Push
Hose id 1-1/2" ×
4.9 ft (id 38 mm ×
1.5 m long)
Fig. 12
15

Advertisement

Table of Contents
loading

Table of Contents