Table 3. Serial Cable for PX5nnn Series Controllers
Pin
RS-232 Assigned
1
Data Carrier Detect (DCD)
2
Receive Data (RXD)
3
Transmit Data (TXD)
4
Data Terminal Ready (DTR) 1 and 6 DCD and DSR
5
Signal Ground
6
Data Set Ready (DSR)
7
Request to Send (RTS)
8
Clear to Send (CTS)
9
Not Used
Sleeve 5V (not used)
Pin
Ground

Sensor Connection

Each controller has a unique set of sensor ZIF mating connectors. The schematics define
the number of pins and the BOM defines the vendor part number for each. The sensor
flex tails should be plugged directly into the controller connectors.
Note: ZIF connectors can be fragile. Do not force these connectors open. These ZIF
connectors are not removable; they must be opened/released to connect or disconnect a
cable from them.
Take the tail straight from the sensor and carefully align with the ZIF connector.
PC Side (9-Pin D)
Jumpered to:
4 and 6 DTR and DSR
1 and 4 DCD and DSR
3M Touch Systems, Inc. Proprietary Information
3M™ Multi-Touch ASIC Controller Reference Guide
Controller Side
(8-Pin Molex)
Pin Description
8
DCD, DTR, DSR
2
Transmit Data (TXD)
3
Receive Data (RXD)
8
DCD, DTR, DSR
5
Power supply ground
8
DCD, DTR, DSR
1
Request to Send (RTS)
4
Clear to Send (CTS)
Do not ground
6
DC power jack (Not Used)
7
Cable shield connected to
ground. DC power jack
ground