3M™ Multi-Touch ASIC Controller Reference Guide
Table 11. Power On Check Bit Fields
Bit Number
0
Not used
1
ROM_ERROR
2
PWM Error
3
NOV_ERROR
4
HDW_ERROR
5
Not used
6
Not used
7
Not used
Last Command Request Status – This field is used to determine whether the last request
was processed successfully. It is also used to track the progress of a multi-stage request,
such as 2 point calibration. The Status Request does not affect the contents of this field,
i.e., successful or unsuccessful processing of a previous status request does not cause the
command status field to be updated.
Table 12. Valid Command Status Field Entries
Response
Description
0
Failure in command processing
1
Command being processed
2
Stage 1 processing complete (for multi-stage commands)
3
Command complete
4
Soft Reset Occurred
5
Hard Reset Occurred
6-7
Not used
Get Feature – Get Max Count
This is a request to send information that indicates the maximum number of simultaneous
touches supported by the controller.
Table 13. Get Max Count Setup Stage
Offset
Field
0
bmRequestType
1
bRequest
2
wValue
4
wIndex
6
wLength
Description
Size
Value
1
0xA1
1
0x01
2
0x0312
2
0
2
2
3M Touch Systems, Inc. Proprietary Information
Notes
Code area checksum error
Touch screen not connected or potential problem.
Parameter Block1 checksum error
Problem with ADCs
Description
Class,D2H,Interface
Get Report
msb=03=Feature
lsb=12 Feature Report ID
Always 0
Always 2
19