Dover PSG Wilden PX220 Engineering, Operation & Maintenance

Dover PSG Wilden PX220 Engineering, Operation & Maintenance

Metal pump

Advertisement

Quick Links

EOM
Engineering
Operation &
Maintenance
PX220/PX230
Metal Pump
Where Innovation Flows
wildenpump.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSG Wilden PX220 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dover PSG Wilden PX220

  • Page 1 Engineering Operation & Maintenance PX220/PX230 Metal Pump Where Innovation Flows wildenpump.com...
  • Page 2: Table Of Contents

    T A B L E O F C O N T E N T S SECTION 1 CAUTIONS—READ FIRST! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SECTION 2 WILDEN PUMP DESIGNATION SYSTEM .
  • Page 3: Cautions-Read First

    S e c t i o n 1 C A U T I O N S — R E A D F I R S T ! CAUTION: Do not apply compressed air to the exhaust port CAUTION: Canadian Standards Association (CSA) —...
  • Page 4: Wilden Pump Designation System

    S e c t i o n 2 W I L D E N P U M P D E S I G N A T I O N S Y S T E M LEGEND PX220/PX230 METAL X PX220 / XXXX X / XXX / XX / X XX / XXXX 25 mm (1") Pump O-RINGS...
  • Page 5 S e c t i o n 3 H O W I T W O R K S — P U M P The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke. OUTLET OUTLET OUTLET...
  • Page 6: Dimensional Drawings

    S e c t i o n 4 D I M E N S I O N A L D R A W I N G S P X220 Meta l —T hreaded DIMENSIONS ITEM METRIC (mm) STANDARD (inch) 14.2 10.0 11.3 15.1...
  • Page 7 S e c t i o n 4 D I M E N S I O N A L D R A W I N G S P X23 0 St ainl ess Steel —Fla nged DIMENSIONS ITEM METRIC (mm) STANDARD (inch) 14.7 11.3...
  • Page 8 S e c t i o n 5 B N O T E S...
  • Page 9 PX220/PX230 P X 2 2 0 / P X 2 3 0 P E R F O R M A N C E...
  • Page 10: Operating Principle

    S e c t i o n 5 B Pro-Flo X Operating Principle The Pro-Flo X™ air distribution system with the control dial, the operator can select the optimal revolutionary Efficiency Management System (EMS) balance of flow and efficiency that best meets the offers flexibility never before seen in the world of application needs.
  • Page 11: How To Use This Ems Curve

    H O W T O U S E T H I S E M S C U R V E Example 1 SETTING 4 PERFORMANCE CURVE EMS CURVE Figure 1 Figure 2 0.58 flow multiplier Example data point = Example data point = 0.48 air multiplier This is an example showing how to determine flow rate and...
  • Page 12 H O W T O U S E T H I S E M S C U R V E Example 2.1 SETTING 4 PERFORMANCE CURVE EMS CURVE EMS Flow Settings 1 & 2 Figure 4 Figure 5 10.2 0.49 Example data point = flow multiplier This is an example showing how to determine the inlet air...
  • Page 13 H O W T O U S E T H I S E M S C U R V E Example 2.2 SETTING 4 PERFORMANCE CURVE EMS CURVE EMS Air Settings 1 & 2 Figure 6 Figure 7 10.2 0.40 Example data point = Example data point = air multiplier...
  • Page 14: Px220/Px230 Metal Rubber-Fitted

    P E R F O R M A N C E WILDEN PUMP & ENGINEERING, LLC PX220/PX230 Performance...
  • Page 15: Px220/Px230 Metal Tpe-Fitted

    P E R F O R M A N C E PX220/PX230 Performance WILDEN PUMP & ENGINEERING, LLC...
  • Page 16: Px220/Px230 Metal Reduced-Stroke Ptfe-Fitted

    P E R F O R M A N C E WILDEN PUMP & ENGINEERING, LLC PX220/PX230 Performance...
  • Page 17: Px220/Px230 Metal Full-Stroke Ptfe-Fitted

    P E R F O R M A N C E PX220/PX230 Performance WILDEN PUMP & ENGINEERING, LLC...
  • Page 18: Suction-Lift Curves

    S e c t i o n 5 D S U C T I O N - L I F T C U R V E S P X 2 2 0 / P X 2 3 0 M E T A L S U C T I O N - L I F T C A P A B I L I T Y Suction-lift curves are calibrated for...
  • Page 19 S e c t i o n 6 S U G G E S T E D I N S T A L L A T I O N Wilden pumps are designed to meet the performance ELEVATION: Selecting a site that is well within the pump’s ®...
  • Page 20 S U G G E S T E D I N S T A L L A T I O N This illustration is a generic GAUGE representation of an air-operated (OPTIONAL) double-diaphragm pump. EQUALIZER SHUT-OFF SURGE DAMPENER VALVE (OPTIONAL) DISCHARGE FLEXIBLE CONNECTION...
  • Page 21: Section 7 Disassembly / Reassembly

    S U G G E S T E D O P E R A T I O N & M A I N T E N A N C E OPERATION: The Pro-Flo X™ pumps are pre-lubricated discharge pressure or increasing the air inlet pressure. and do not require in-line lubrication.
  • Page 22 S e c t i o n 7 P U M P D I S A S S E M B L Y To o l s R e q u i r e d : CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the •...
  • Page 23 S e c t i o n 4 P U M P D I S A S S E M B L Y Step 4 Step 5 Step 6 Remove discharge valve Using a 13 mm (1/2") wrench, Remove the inlet valve balls, seats balls, seats valve...
  • Page 24: Grounding Strap For Csa Pumps

    P U M P D I S A S S E M B L Y Step 10 Step 11 Step 12 After loosening removing To remove the remaining diaphragm Inspect diaphragms, outer the outer piston the diaphragm assembly from the shaft, secure inner pistons for signs of wear.
  • Page 25: Air Valve Disassembly

    A I R V A L V E D I S A S S E M B L Y To o l s R e q u i r e d : CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the •...
  • Page 26 A I R V A L V E D I S A S S E M B L Y Step 4 Step 5 Step 6 Remove air valve spool from air Remove air valve end cap to expose Remove pilot spool sleeve retaining valve body by threading one air air valve spool by simply lifting up snap ring on both sides of center...
  • Page 27 A I R V A L V E D I S A S S E M B L Y Step 9 Check center section Glyd™ rings for signs of wear. If necessary, remove Glyd™ rings with O-ring pick and replace. S U B M E R S I B L E P R O - F L O X ™...
  • Page 28: Reassembly Hints & Tips

    R E A S S E M B L Y H I N T S & T I P S REASSEMBLY: SHAFT SEAL INSTALLATION: Upon performing applicable maintenance to the air PRE-INSTALLATION distribution system, the pump can now be reassembled. •...
  • Page 29 N O T E S...
  • Page 30: Px220/Px230 Metal

    S e c t i o n 8 e x p l o d e d v i e w & p a r t s l i s t i n g S e c t i o n 8 E X P L O D E D V I E W &...
  • Page 31 E X P L O D E D V I E W & P A R T S L I S T I N G PX220/PX230 METAL P A R T S L I S T I N G PX220/AAAAA PX220/WWAAA PX220/SSAAA Item...
  • Page 32: Section 9 Elastomer Options

    S e c t i o n 9 E L A S T O M E R O P T I O N S PX220/PX230 Metal REDUCED- FULL-STROKE FULL-STROKE REDUCED- STROKE VALVE FULL-STROKE BACKUP STROKE BACKUP VALVE VALVE SEAT MANIFOLD DIAPHRAGM DIAPHRAGMS DIAPHRAGMS...
  • Page 33 N O T E S...
  • Page 34 N O T E S...
  • Page 35 W A R R A N T Y Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation. Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes first.
  • Page 36 This is a non-contractual document. 11-2018 Authorized PSG Representative: 22069 Van Buren St., Grand Terrace, CA 92313-5607 P: +1 (909) 422-1730 • F: +1 (909) 783-3440 Copyright ©2018, PSG ® , A Dover Company wildenpump.com WIL-11610-E-02 REPLACES WIL-11610-E-01...

This manual is also suitable for:

Psg wilden px230