Technical specifications of the input
Rated input voltage U
in
Input frequency f
in
Radio interference level
Switching frequency f
sw
Connector type
Technical specifications of the outputs
Output voltage tolerance ∆U
Overvoltage protection
Noise ∆U
LF
Noise ∆U
HF
Regulation
Line regulation
Load regulation
Short-circuit current I
max
Settling time t
load variations
R
Temperature coefficient ε
8
out
EN 61000-6-2 / EN 61000-4-2
Contact discharge: 4 kV
(air discharge): 8 kV
EN 61000-6-2 / EN 61 000-4-4
Symmetrical: 2 kV
Asymmetrical: 2 kV
EN 61000-6-5 / EN 61 000-4-5
Symmetrical: 1 kV
asymmetrical 2 kV
EN 61000-6-2 / EN 61000-4-3
10 V, 3 V, 1 V (80 MHz ... 2.7 GHz)
EN 61000-6-2 / EN 61000-4-6
10 V
eff
EN 61000-6-2 / EN 61000-4-11
140 × 85 × 35 mm
172.7 × 85 × 35 mm
720 g
100 to 240 VAC
50/60 Hz
EN 55011/B
approx. 70 kHz typ.
7/8", 2-pin + PE
6 ... 8 mm
U
≤ +2 % / -1 %
out nom
at U
= 230 VAC, f = 50 Hz
in
U
+20 % typ.
out nom
≤ 1 % U
out
at U
= min., BW: 1 MHz
in
≤ 2 % U
out
U
= min., BW: 20 MHz
in
≤ 1.0%
at U
= min./max.
in
≤ 1.0%
at I
= 10...90...10%
out
105 ... 130 % I
nom
at I
= 3 A (+50 °C)
nom
< 5 ms
at I
= 10...90...10 %
out
0.01 % / K
at T
= -25 °C ... +70 °C