Download Print this page

Scotsman NWH Series Technical Service Training page 46

Dice & halfdice cubers

Advertisement

When the Harvest Cycle starts ,
Drain Valve and Water Pumps
purge out old water for a pre-set
time according with Dip-SWITCH
n.6-7.
After 20" of operation of Water
Drain Valve also the Water inlet
Valve will be activated for 10" in
order to have a short flush of
fresh water into the water sump
while the Water Pump and Drain
Valve are still in operation.