W.E.ST. POS-124-U-PFN Technical Documentation Manual page 52

Two axes positioning and synchronisation control module with integrated profinet io interface and ssi sensor interface
Hide thumbs Also See for POS-124-U-PFN:
Table of Contents

Advertisement

Description of the status byte 1:
Nr.
Bit
Name
1
0
Senserror_1
2
1
-
3
2
-
4
3
-
5
4
Syncwin
6
5
Poswin_1:D
7
6
Poswin_1:S
8
7
Ready_1
Description of the status byte 2:
Nr.
Bit
Name
1
0
Senserror_2
2
1
-
3
2
-
4
3
-
5
4
-
6
5
Poswin_2:D
7
6
Poswin_2:S
8
7
Ready_2
Page 52 of 65
Description
Sensor error. Monitored are SSI and 4... 20 mA input
signals.
Attention: Inverted signal, an error exists if the bit is not
set.
-
-
-
Synchronous run monitoring. Message for being within the
preset window for synchronous error.
Dynamic position monitoring. Message for being within the
preset window for following error in NC mode.
Static position monitoring. Message for reaching the target
position within the preset tolerance (SDD mode).
General operational readiness of the axis. ENABLE signals
are available and no error was detected.
Description
Sensor error. Monitored are SSI and 4... 20 mA input
signals.
Attention: Inverted signal, an error exists if the bit is not
set.
-
-
-
-
Dynamic position monitoring. Message for being within the
preset window for following error in NC mode.
Static position monitoring. Message for reaching the target
position within the preset tolerance (SDD mode).
General operational readiness of the axis. ENABLE signals
are available and no error was detected.
POS-124-U-Ethernet
Type
Default
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
Type
Default
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
08.11.2018