HCK4-4 Check Valve
INTRODUCTION
The HCK4 series of dependable, compact, rugged
in-line check valves (disc type non-return valves) is
ideally suited for refrigerant flow control applications.
Valves open wide for flow in the arrow direction on the
valve body. Valves close quickly and reliably when
flow reversals occur.
Plated bodies and stainless steel seat discs and
springs enable them to withstand expected industrial
refrigeration conditions. Furthermore, these check
valves can be mounted in any position and close-
coupled to other valves.
ADVANTAGES
These compact check valves offer reliable operation
regardless of position. Corrosion resistant stainless
steel seat disc. Metal-to-metal seats facilitate durable,
tight closing of valves.
APPLICATIONS
These in-line check valves are designed to provide
refrigerant flow control to hot gas lines, liquid lines,
compressor discharge lines, suction lines, and hot
gas heated drain pans.
These valves are not recommended for use with
pulsating loads such as low speed compressor
discharge and screw compressor side port applications.
For applications such as these, use Hansen HCK1
piston type check valves.
Specifications, Applications,
Service Instructions & Parts
HCK4 IN-LINE CHECK VALVES
5/8" THRU 4" PORT
(16 mm THRU 100 mm)
Flanged
3/8" thru 4"
(10 mm thru 100 mm)
FPT, SW, WN, ODS
for refrigerants
KEY FEATURES
STAINLESS STEEL SEAT DISC
LAPPED METAL SEATING
DUAL BODY/CARTRIDGE SEALS
ADDITIONAL FEATURES
Mounts in any position
Less than 1 psid wide opening pressure
Can be close-coupled
Low bubble leakage tolerance
For Ammonia, R22, R134a, CO2 and other approved
refrigerants
U.L. Listed
Bulletin C401e
JUL 2006
CLOSING SPRING

Advertisement

loading

Summary of Contents for Hansen HCK4-2

  • Page 1 These valves are not recommended for use with pulsating loads such as low speed compressor discharge and screw compressor side port applications. ADDITIONAL FEATURES For applications such as these, use Hansen HCK1 Mounts in any position piston type check valves. Less than 1 psid wide opening pressure...
  • Page 2 Operating Temperature: -60ºF to 240ºF (-50ºC to perpendicular to pipe. Also, gaskets should be lightly 115°C) INSTALLATION DIMENSIONS INSTALLATION DIMENSIONS oiled and all bolts must be tightened evenly. INSTALLATION DIMENSIONS DIMENSION HCK4-2 HCK4-3 HCK4-4 HCK4-5 HCK4-7 HCK4-8 HCK4-9 HCK4-0 HCK4-1 LETTER 5/8”...
  • Page 3: Parts List

    PARTS LIST HCK4-2 (2-BOLT) HCK4-2 (2-BOLT) HCK4-2 (2-BOLT) ITEM DESCRIPTION QTY PART NO Valve Assembly Kit Above kits consist of: Seat Disc 72-0069 Closing Spring 72-0070 Seat Cartridge 72-0068 Seat Cartridge O-Ring 72-0071 Flange Gasket 70-0065 Body, HCK4-2 72-0067 Bolt (7/16" - 14x3.25") 70-0225 Nut (7/16"...
  • Page 4 – 4-1/8” and valves. Follow the guidelines in the caution section. HCK4-2 close-couples to HS6 & HS8 Solenoid Valves. Loosen each flange nut on the check valve. Break HCK4-3, -4, & -5 close-couples to HS7 Solenoid Valve. each flange gasket seal. Carefully loosen flange bolts FPT available only 3/8”...