clips), press the DOWN key to select the "Video" setting. Press the ENTER key to "Execute" (Set) the new
setting you've selected for this parameter.
Now press the RIGHT key to move to another parameter in the Menu. Pressing it three times will take
you to "Video Size". Try using the UP and DOWN keys to scroll through the range of settings, then press
ENTER to lock in your setting for the resolution of each video clip the camera shoots.
Pressing the RIGHT key several more times will get you to the "Default Set" parameter. Highlight or
select "Execute" (using UP or DOWN) and press ENTER to restore all parameters (including the Mode
and Video Size parameters you changed a minute ago) back to their original factory default settings. The
default settings for each parameter are indicated in bold type in the SETUP Menu tables on the next
several pages.
Field Scan 2x with Live Trigger Feature
Field Scan is a revolutionary new feature for the Bushnell Core Trail Camera, which allows you to
monitor your food plots or field edges with time lapse images or video. When set to "On", the Core Trail
Camera will take a photo (or record a video clip) automatically at your choice of intervals (for example,
once every five minutes) during one or two blocks of time you set up for each day, without requiring a
trigger from an active animal. This has the advantage of giving you the ability to monitor the edge of a
field that might be 50 or 150 yards away from the camera out of the PIR sensor's range. The result is an
effective range much greater than it would normally be, with the camera dependent on triggers
generated by nearby animals. This is a great tool for hunters to scout an entire field with only one
camera.
If an animal does enter the area covered by the PIR sensor and generate a trigger event during a time in
between the Field Scan intervals you set, the camera will capture an image or video just as it normally
would, based on your other menu settings. Here's how to setup and use Field Scan (be sure you've set
the current time in "Set Clock" first, so your Field Scan recording will stop and start at the correct times
of day):
1. Move the main switch to SETUP, then press MENU.
2. Keep pressing the RIGHT key, stepping through the Setup Menu until you reach
Field Scan.
3. Press the UP key to select On, and press OK (Step 1, pg.17). You will see "A", representing the first
block of time you can define (a second block of time later in the day, "B" can also be setup if you wish).
Press OK (Step 2). This takes you to the screen to set Start and Stop times, which determines the clock
times when the first block of Field Scan recording will begin and end for each day.
You can set these times to the exact hour and minute you want, for a recording "window" that lasts
anywhere from just a minute to a full 24 hours.
4. Set the [Start] and [Stop] times, beginning with the Start hour, using the UP/DOWN keys to change
the setting (Step 3). The hour setting is based on a 24-hour clock, with "00" hours = midnight, "12" hours
= noon, "23" hrs = 11PM, etc. To move to the next setting, press the RIGHT key, change the minute for
the Start time with UP/DOWN, then on to the hour and minute settings for the Stop time.
5. After you finish setting the Stop minutes, press OK to confirm your settings for the first block of Field
Scan recording. If desired, you can create a second block of time by pressing the DOWN key to select "B"
(Step 4), then press OK and follow the same process to set Start and Stop times for Field Scan block "B"