Oil Separating Procedure - TOTALINE TTL-RECO250S User Manual

Refrigerant recovery unit
Table of Contents

Advertisement

Available languages

Available languages

 
1) Make  sure all  connections are  correct and  tight. 
2) Make sure the port of drain valve is closed. 
3) Make sure the MODE valve on RECOVERY position  
4) Open the liquid port of the storage tank. 
5) Open the output port of the unit and liquid port on the manifold 
gauge set. 
6) Turn the power switch to ON. Open the input valve slowly to liquid 
position.  Run until the recovery is achieved. 
7) Turn the power switch to OFF. Open the port of oil drain valve, 
and drain the oil into a suitable container, then close The oil 
drain port. 
8) Disconnect all hoses 
 
 