Gicam RQ Operational Handbook

Gicam RQ Operational Handbook

Loading cells digital amplifier
Hide thumbs Also See for RQ:

Advertisement

LOADING CELLS DIGITAL AMPLIFIER
RQ
OPERATIONAL HANDBOOK
SOFTWARE CODE: PTRQ01
VERSION: Rev.0.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RQ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gicam RQ

  • Page 1 LOADING CELLS DIGITAL AMPLIFIER OPERATIONAL HANDBOOK SOFTWARE CODE: PTRQ01 VERSION: Rev.0.1...
  • Page 2: Data Programming

    Pag. WEIGHT VIEW AND RESET AND ANALOG OUTPUT ADJUSTMENT Pag. CONFIGURATION MENU Pag. 5 - 6 - 7 WEIGHT CALIBRATION Pag. LOGIC OUTPUT Pag. ANALOG OUTPUT Pag. SERIAL PROTOCOL Pag. 11-12 PROBLEM SOLUTION Pag. RQ device operational handbook Pag. 1...
  • Page 3: Main Display

    OVERLOAD SIGNAL When the gross weight on the scale abounds the maximum weight allowance by 9 divi- sions, this signal is shown on display. No weight signal. Pag. 2 RQ device operational handbook...
  • Page 4: Key Functions

    Up the blinking character If the blinking char is the last down, pressing the key is going to save the value and goes back to Following char selection main menu. Down the blinking character RQ device operational handbook Pag. 3...
  • Page 5 “ MIN”). To execute changes over the 10% limit a new calibration as to be done or the lower limit of the analog output in the main menu has to be changed. Pag. 4 RQ device operational handbook...
  • Page 6: Configuration Menu

    See page 8. DISPLAY VIEW AT START J1SVA With this parameter is chosen the data to show at device start up; you can choose between ANALG (analog output in Volt) and GROSS (gross weight). RQ device operational handbook Pag. 5...
  • Page 7 Set the setpoint for output 2. The maximum value to set is like the load of the cells. Default ISTERESI 1STR Isteresi value regarding the set point. Default 0. BAUD RATE COM1 Values: 9600 / 19200 / 38400/ 57600 / 115200 bit / sec. BAUD1 Default = 9600 Pag. 6 RQ device operational handbook...
  • Page 8: Serial Address

    0 to 20 mSec. PROF : Bus PRFIBUS (if port present). ANALOG MENU 1 AN-1 Analog output settings in mA. See page 10. ANALOG MENU 2 AN-2 Analog output settings in mA. See page 10. RQ device operational handbook Pag. 7...
  • Page 9: Zero Calibration

    It is possible to repeat the operation. LOOK OUT: If the device is turned off before leaving the setup menu all the programming options selected will not be saved. Pag. 8 RQ device operational handbook...
  • Page 10 Contact open when gross weight is over “set1 + isteresi” output 2 : contact closed when gross weight is minor than “set2 - isteresi” Contact open when gross weight is over “set2 + isteresi” RQ device operational handbook Pag. 9...
  • Page 11: Analog Output Range

    Use the keys to contro analog output. Keep the key pressed for a quick varia- tion. Change da 0 mode to FS mode and back with the key. Press together to leave the function. Pag. 10 RQ device operational handbook...
  • Page 12: Profibus Protocol

    <gross> = gross weight in 7 ASCII char. PROFIBUS PROTOCOL ANYBUS IC SCI input data area Profibus address Variabils Error registry 0x0000 Status register 0x0001 Gross weight 0x0002 0x0003 Analog output in Volt 0x0004 RQ device operational handbook Pag. 11...
  • Page 13 Bit 2 Bit 1 Bit 0 offrange overload underload Zero Analog Weight Weight Zero Checked sign sign stable Center Address Description 0x1000 Command Register If Command Register = 8 the gross weight cancelation commences. Pag. 12 RQ device operational handbook...
  • Page 14: Troubleshoting Guide

    Check the right connection to ana- work properly way. log output, AN-1 menu is about the output in mA while AN-2 is about the one in Volt. Check if the data are right and the correct calibration. RQ device operational handbook Pag. 13...