  • Page 1 VOLCANO GAS HOB Instruction Manual LKGH-8602MB LKGH-8603MB www.lebensstilkollektion.com...
  • Page 3: Table Of Contents

     Table of Contents  Components and features  Description of the appliance  Using the gas hob  Maintenance  Practical Advice  Safety  Troubleshooting  Installation instructions...
  • Page 4: Components And Features

     Components and Features A. Wok burner B. Support Grid for Cookware C. Control Knobs for Gas Burners D. Ignition for Gas Burners E. Safety Device F. Energy gathered pan G. Auxiliary burner...
  • Page 5: Description Of The Appliance

     Description of the appliance This built in gas hob is supplied with 2 burners(LKGH-8602MB) or 3 burners(LKGH-8603MB) on a glass panel. Each burner is operated by a FSD/ plug type gas valve, controlled by a metal control knob positioned on the top of the panel.
  • Page 6: Using The Gas Hob

     Using the gas hob The position of the corresponding gas burner is indicated on each control knob. Gas Burners Choose appropriate diameter of the cookware being used. The diameter of the cookware used should be larger than the burners in order to save energy.
  • Page 7: Maintenance

     Maintenance Before cleaning or performing maintenance on your appliance, disconnect it from the gas supply. To extend the life of the cooktop, ensure that it is cleaned carefully and thoroughly on a frequent basis, keeping in mind the following: ...
  • Page 8: Practical Advice

     Practical Advice Practical Advice on Using the Burner For best performance,follow these general guidelines:  Use the appropriate cookware for each burner(see table below as reference)in order to prevent the flame from reaching the sides of the cookware;  When the contents come to a boil,turn the knob to “Low” Burner Φ...
  • Page 9: Safety

     Safety To maintain the Efficiency and Safety of this appliance, we recommend: Call only the Service Centers authorized by the manufacturer or authorized service agent in order to avoid a hazard. Always use original Spare Parts. This manual is for a class 3 built-in or class 2 built suitable with a built in oven beneath.
  • Page 10 The assistance of qualified personnel must be called upon in the following cases: Installation (in accordance with the manufacturer’s instructions) When in doubt about the operation of the appliance; Contact service centers authorized by the manufacturer, its service agent in the following cases: When in doubt about the condition of the appliance after having removed the packing;...
  • Page 11: Troubleshooting

    Troubleshooting  It may occur that the cooktop does not function or does not function properly. Before calling the customer service for assistance, please see what can be done. First of all, check to see that there are no interruptions in the gas and battery supplies, and, in particular, that the gas valves for the mains are open.
  • Page 12: Installation Instructions

     Installation Instructions for Built-In The following Instructions are intended for the installer so that the installation and maintenance procedures may be followed in the most professional and expert manner possible. Positioning This appliance may only be installed and operated in properly ventilated rooms in compliance with provision laid down by current regulations and standards,The following requirement must be observed: A) The room must be fitted with a ventilation system which vents smoke and...
  • Page 13 B) The room must also allow for the influx of the air needed for proper combustion.The flow of air for combustion purposes must not be less than 2m³ /h per kW of installed capacity.The supply of said air can be effected by means of direct influx from the outside through a duct with a inner cross section of at least 100 ㎡...
  • Page 14 D)Liquefied petroleum gases are heavier than air and as a result,settle downwards.Rooms in which LPG tanks are installed must be fitted with ventilation openings to the outside in order to allow the gas to escape in the event of a leak.Therefore,LOG tanks,whether empty or partially full,must not be installed or stored in rooms or spaces below ground level(cellars,etc.).It is also a good idea to keep only the tank currently being used in the room,making sure that it is not near sources of heat(ovens,fireplaces,stoves,etc.) that could raise...
  • Page 15 Should the cooktop be installed directly under a cupboard, it should be at least 720 mm (millimeters) from the top, as shown in Fig. C. The dimensions of the cutout for the appliance must be those indicated in the Fig D. Clamps are provided to fasten the cooktop to counters measuring from 20 to 60 mm in thickness.
  • Page 16 The hob can also be installed above built-in provided with cooling ventilation. In the event the cooktop is installed above a built-in oven,a wood panel must be inserted as insulation.This panel must be placed at about 50 mm from the bottom of the cooktop itself.
  • Page 17 The cylinder tap have to be readily accessible. Over flow of liquid from pans of the hotplate shall not fall onto cylinder or its accessories. The flexible tube shall not be in contact with sharp edges.No internal connection shall exist between the cylinder compartment and the different parts of the appliance where burners are placed.
  • Page 18 Gas Connection to Flexible Steel Pipe The gas feed connector to the appliance is a threaded, male 1/2” connector for round gas pipe. Only use pipes, tubes and gaskets that comply with current safety codes. The maximum length of the flexible pipes must not exceed 200cm.
  • Page 20 Distributed by: Kollektion Distribution Sdn.Bhd.(596854-A) Lot 11B,Jalan 223,Section 51A, 46100 Petaling jaya, Selangor Darul Ehsan,Malaysia. Tel:+603-7954 5200 Fax:+603-7954 5705 www.lebensstilkollektion.com...