EH330, EH430 and ECC Condensing Unit
Remote Low Side Cuber Service Manual

Refrigeration Data - 1800

60
50
40
30
20
10
0
Discharge pressure at 90/70 will peak at 240 - 250 PSIG, operate between 230 and 240 and drop to 170
during harvest.
Typical cycle time is 13-14 minutes, including 1:30 for harvest.
July 2013
Page 44
ECC1800 with EH430 90/90/70
Freeze Cycle Low Side Pressure