Complete The Installation - Scotsman EH330 C Series Service Manual

Table of Contents

Advertisement

EH330, EH430 and ECC Condensing Unit
Remote Low Side Cuber Service Manual

Complete the Installation

After the utilities and refrigeration connections have
been made, secure the unit to the dispenser or bin
top.
Secure ice making section to dispenser or bin
adapter.
Use strap/clips to secure unit. On some bins or
dispensers it may be necessary to drill small holes
and use field supplied sheet metal screws to secure
the ice making head to that bin, dispenser or adapter.
If the ice maker & bin or dispenser is not yet in its final
position gently move it there.
Note: The refrigerant lines above the machine must
be able to move freely while the machine is being
moved into position.
Final Check List Before Initial Start Up
1. Confirm that the ice making section is installed
indoors in a controlled environment.
2. Confirm that all packing materials have been
removed from all products.
3. Confirm that the ice making section is level.
4. Confirm that all the refrigerant connections have
been made and checked for leaks.
5. Confirm that the proper power supply has been
turned on to the condensing unit.
6. Confirm that cold, potable water has been supplied
to the ice making section and checked for leaks.
7. Confirm that the water supply is adequate.
8. Confirm that there is adequate water pressure and
that any water filters have been checked to confirm
that the cartridges do not need changing.
9. Confirm that the proper size drain tubing has been
installed and properly routed.
10. Confirm that the ice making section has been
connected to the proper power supply.
11. Confirm that the interconnecting wire has been
routed and connected between the ice making section
and the condensing unit.
July 2013