Download Print this page

Panasonic HG-C1000L Series Instruction Manual page 6

Micro laser distance sensor for io-link (cmos)

Advertisement

Setting
Default setting
Description
Set the response time.
Response
"
speed
"
"
Output
Select the control output operation mode.
operation
"
Set the sensing output.
"
"
mode)
Sensing
"
output
mode)
"
mode)
"
"
HG-C1030L3-P:
HG-C1050L3-P
Set the hysteresis width.
HG-C1030L3-P: 0.001 to 5.00mm
HG-C1050L3-P: 0.01 to 15.00mm
HG-C1100L3-P:
Hysteresis
HG-C1100L3-P: 0.02 to 35.00mm
HG-C1200L3-P: 0.1 to 80.00mm
HG-C1200L3-P:
HG-C1400L3-P: 0.2 to 200.00mm
HG-C1400L3-P:
HG-C1030L3-P:
Set shift amount of threshold value in limit
teaching.
HG-C1050L3-P
Set the shift amount to a value that is twice the
value of hysteresis or more.
Shift
HG-C1100L3-P:
HG-C1030L3-P□: 0.002 to 10.00mm
amount
HG-C1050L3-P□: 0.02 to 30.00mm
HG-C1200L3-P:
HG-C1100L3-P□: 0.04 to 70.00mm
HG-C1200L3-P□: 0.2 to 160.0mm
HG-C1400L3-P:
HG-C1400L3-P□: 0.4 to 400.0mm
Set the timer operation. The timer time is fixed
at 5ms.
"
Timer
"
"
"
Set the timer period when the timer setting is
set to "OFF-delay timer," "ON-delay timer" or
"One-shot timer."
Timer
"
period
"
"
5,000ms
The display of the measured value can be
changed.
Display
"
"
"
Set the control output and the analogue output
operation when a measurement error occurs
(insufficient light intensity, saturation of light
Hold
intensity, out of measurement range).
"
"
The digital display can be set to go OFF when
key operation is not performed for 30 seconds.
ECO
Current consumption can be reduced.
"
"
Return to the default setting (factory setting).
Reset
"
"
": High precision 10ms
": Standard 5ms
": High speed 1.5ms
": Light-ON, "
": Dark-ON
": Normal sensing mode
": 1-point teaching (Window comparator
": 2-point teaching (Window comparator
": 3-point teaching (Window comparator
": Rising differential mode
": Trailing differential mode
": No timer,
": OFF-delay timer
": ON-delay timer
": One-shot timer
": 5ms, "
": 10ms, "
": 25ms,
": 50ms, "
": 100ms, "
": 250ms,
": 500ms, "
": 1,000ms, "
":
": Normal
": Invert
": Offset
": Hold OFF
": Hold ON
": ECO OFF
": ECO ON
": Reset NG
": Reset OK
Procedure
Measurement display
DOWN: Press for 3 seconds
Response
High precision
time setting
Output operation
Light-ON
setting
Normal sensing
Sensing output
mode
setting
Trailing differential
mode
Hysteresis setting
Hysteresis width
Shift amount setting
No timer
Timer setting
Timer period setting (only when "OFF-delay", "ON-delay" or "One shot" is set for "Timer setting")
Display setting
Normal
Hold setting
Hold OFF
ECO setting
ECO OFF
Reset NG
Reset setting
Response
time setting
6 6
Standard
High speed
Dark-ON
1-point teaching
2-point teaching
(Window comparator
(Window comparator
mode)
mode)
Rising differential
3-point teaching
mode
(Window
comparator mode)
UP key:
Increases the hysteresis width
DOWN key:
Decreases the hysteresis width
UP key:
Increases the shift amount
DOWN key:
Decreases the shift amount
OFF-delay
ON-delay
UP key:
Increases the timer period setting
DOWN key:
Decreases the timer period setting
Invert
Offset
Hold ON
ECO ON
Reset OK
One-shot

Advertisement

loading

This manual is also suitable for:

Hgc1200l3-pHgc1030l3-pHg-c1050l3-pHg-c1400l3-pHg-c1050l3-p-jHgc1030l3-p-j ... Show all