Huawei ES3000 V3 User Manual page 93

Nvme pcie ssd
Table of Contents

Advertisement

ES3000 V3 NVMe PCIe SSD
User Guide
maximum capacity
current capacity
volatile write cache
serial number
model number
firmware version
NVMe version
device status
device status in the command output indicates the SSD controller health status.
The value healthy indicates that the device is healthy.
The value warning indicates that an exception occurs on the device. For details, see
Step 2 Determine the SMART status of the disk. For details, see
Information About a
# Query the SMART information of nvme0.
[root@localhost tool]# hioadm info -d nvme0 -s
critical warning
composite temperature
available spare
available spare threshold
percentage used
data units read
data units written
host read commands
host write commands
controller busy time
power cycles
power on hours
unsafe shutdowns
media and data integrity errors: 0
number of error information log entries: 0
warning composite temperature time: 0 min
critical composite temperature time: 0 min
data status
Critical Warning: Critical exceptions occur on the device, and emergency handling is
required.
Issue 20 (2019-02-27)
formatted metadata size:
: 1.6TB
: 1.6TB
: Enable
: 0503023HDCN107C80013
: HWE32P430016M00N
: 2.14
: 1.2
: healthy
Device.
: no warning
: 308 degrees Kelvin (35 degrees Celsius)
: 100%
: 10%
: 0%
: 68.8 MB
: 0.0 MB
: 17748
: 0
: 0 mins
: 89 times
: 1164 h
: 35 times
: OK
Copyright © Huawei Technologies Co., Ltd.
5 Maintenance and Upgrade
0 Byte
6.1.3 Querying the SMART
Step
2.
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents