THOMSON marathon TS 910 Series Quick Start Manual

THOMSON marathon TS 910 Series Quick Start Manual

Hide thumbs Also See for marathon TS 910 Series:

Advertisement

PM 148 Rev 1 16/07/27
HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH
Read and understand this quick start guide before installing and operating the transfer switch
The installer is responsible for compliance with national electrical code requirements with respect to installation of this equipment.
Many components of this equipment operate at line voltage. DO NOT TOUCH. Use only electrically isolated tools.
Install and close all covers before applying power to this equipment
Do not open covers to equipment until ALL power sources are disconnected
This equipment must be installed and serviced only by qualified electrical personnel utilizing safe work practices and appropriate Personal
Protective Equipment (PPE).
Failure to do so may cause personal injury or death
Introduction ............................................................................................................................... 2
Check Equipment Delivery....................................................................................................... 2
Check Line Voltage/Amperage ................................................................................................ 2
Installation Requirements ........................................................................................................ 2
Typical Interior Component Layout Drawing ......................................................................... 4
Power Conductor Installation .................................................................................................. 5
Control Wiring Connections .................................................................................................... 6
TSC 9 Controller Configuration Jumpers ............................................................................... 7
I.
Equipment Energization Procedure ........................................................................................ 8
Pre-Energization Checks .............................................................................................................................................. 8
Equipment Energization ............................................................................................................................................... 9
Transfer Switch Operation ..................................................................................................... 10
Automatic Sequence of Operation ............................................................................................................................. 10
TSC 9 Controller Operation Pushbuttons ................................................................................................................... 10
ATS Manual Operation ............................................................................................................................................... 11
TSC 9 Indication Lights and Pushbuttons ............................................................................ 12
Load Shed ............................................................................................................................... 13
Schematic Diagram ................................................................................................................ 14
THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1
TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com

Quick Start Guide

TS 910 & TS 920
DANGER
Part ID
PAGE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the marathon TS 910 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THOMSON marathon TS 910 Series

  • Page 1: Table Of Contents

    BHP Operator Interface Panel (TS 920 Series Transfer Switch Only) ........ 12 Load Shed ..........................13 Schematic Diagram ........................ 14 THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 2: Introduction

    Commercial Transfer Switch models. For other product types please contact Thomson Power Systems. This quick start guide contains all the information you need to install and set up your new Thomson Power Systems TS 910 or TS 920 Transfer Switch.
  • Page 3 Connect the Bonding Strap to Neutral with the ATS to the front of the door under the circuit breaker toggle THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 4: Typical Interior Component Layout Drawing

    GEN START • LOAD SHED ENCLOSURE • ALARM MOUNTING • REMOTE TEST HOLES (TYP 4) THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 5: Power Conductor Installation

    Once megger testing is complete, re-insert the TSC 9 controller isolation plug (J4). THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 6: Control Wiring Connections

    Terminals are provided for the following control features: Refer to wiring diagram shown below for connection numbers. THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 7: Tsc 9 Controller Configuration Jumpers

    TSC 9 CONFIGURATION JUMPERS Settings Jumpers TSC 9 Printed Circuit Board Jumper Pin Layout THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 8: Equipment Energization Procedure

    Visually verify on the transfer switch enclosure that there are no gaps, holes, or potential for water ingress. THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 9: Equipment Energization

    12. Return the transfer switch to utility power by re-closing the upstream utility breaker. The load should re-transfer back to the utility supply as per Automatic Sequence. THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 10: Transfer Switch Operation

    ALARM RESET: Press and hold the “E” and “T” pushbutton together for 10 seconds until alarm LED goes out. THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 11: Ats Manual Operation

    Once ATS is manually operated to desired position, re-install enclosure cover, then re-energize supply sources to re- energized the load. THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 12: Tsc 9 Indication Lights And Pushbuttons

    Test and Exercise lights flash fast alternatively. All other indicators are off. System Reset BHP Operator Interface Panel (TS 920 Series Transfer Switch Only) THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 13: Load Shed

    Requires additional condition to open control circuit of connected non-essential Current Transformers load THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...
  • Page 14: Schematic Diagram

    PM 148 Rev 1 16/07/27 Part ID N. Schematic Diagram THOMSON POWER SYSTEMS • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: info@thomsonps.com • www.thomsonps.com...