Kärcher HD 4.5/32-4 S Eb Instructions Manual page 11

Hide thumbs Also See for HD 4.5/32-4 S Eb:
Table of Contents

Advertisement

Available languages

Available languages

After the interruption:
Release the trigger gun. To do so,
push the safety catch towards the
back.
Open the hand spray gun.
The appliance will switch on again.
Operational readiness period
On opening the hand-spray gun, the
device starts within the readiness peri-
od. The indicator lamp glows green.
The readiness period is over if the
hand-spray gun remains closed for 30
minutes. The indicator lamp blinks
green.
Reset readiness period
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Customer Service can switch the de-
vice to continuous operations.
Turn off the appliance
Shut off water supply.
Open the hand spray gun.
Switch on the pump with the power
switch and allow to run for about 5-
10 seconds.
Close the hand spray gun.
Set the appliance switch to "0/
OFF".
Pull main plug out of socket with dry
hands only.
Remove water connection.
Activate hand spray gun until de-
vice is pressure less.
Secure the trigger gun. To do so,
push the safety catch towards the
front.
DANGER
Danger of scalding on account of hot
water. The water remaining in the
switched off device can get heated up.
When you remove the hose from the
water inlet, the heated water can spray
out and cause scalding. Do not remove
the hose before the device has cooled
down.
Storing the Appliance
Insert the hand-spray gun in the
holder.
Wind up the high-pressure hose
and hang it over the hose storage.
Wind the connection cable around
the cable holder.
Fasten the plug with the mounted
clip.
Frost protection
ATTENTION
Frost will destroy the not completely
water drained device.
Store the appliance in a frost free area.
If you cannot store it in a frost-free
place:
Emptying the detergent tank (see
"Care and Maintenance/ as re-
quired").
Drain water.
Pump in conventional frost protec-
tion agents through the appliance.
Note:
Use normal glycol-based anti-freezing
agents for automobiles.
Observe handling instructions of the
anti-freeze agent manufacturer.
Operate device for max. 1 minute
until the pump and conduits are
empty.
– 9
EN
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd 4.5/32-4 s ec

Table of Contents