Leuze electronic MA 21 Technical Description page 19

Connector unit as multinet plus slave and as protocol converter
Table of Contents

Advertisement

Specifications of the MA 21
Notice!
The "CODE" data content is only an example; normally the actual user data of the frame are
shown here. Addr. 01 corresponds to slave 1 in the network.
Exiting service mode
As soon as DIP switch 3 is switched back to "Host", the host interface is reactivated.
Data monitoring
When the service interface is in this position, it is possible to "listen" to the data via the
RS 232 as they are transferred from the MA 21 to the host computer (data monitoring).
To do this, you must set your PC / terminal to the host protocol as the host interface is only
passively decoupled with no change of protocol.
Notice!
The configuration programs required for configuring the MA 21 xxx via the service interface,
such as BCL-Config or RF-Config, can be downloaded from
www.leuze.de -> Download -> Identify for BCL, RFID, VR etc.
For further information on configuring see chapter 6.1 "Configuring the interfaces with the
BCL-Config software".
Leuze electronic
MA 21
17