Grant UVT-B-AR Operating Instructions Manual

Uv-cabinet – dna/rna, for versions: v.3gb, v.3gd

Advertisement

Quick Links

UV-cabinet – DNA/RNA
UVT-B-AR
Operating instructions
For versions: V.3GB
V.3GD

Advertisement

loading
Need help?

Need help?

Do you have a question about the UVT-B-AR and is the answer not in the manual?

Questions and answers

Summary of Contents for Grant UVT-B-AR

  • Page 1 UV-cabinet – DNA/RNA UVT-B-AR Operating instructions For versions: V.3GB V.3GD...
  • Page 2 Version 3.01 - May 2013 UVT-B-AR Page 2 Operating instructions...
  • Page 3: Table Of Contents

    Contents Safety ..................4 General Information ..............5 Getting Started................6 Operation of UVT-B-AR .............7 Specifications ................9 Guarantee and service ............10 Declaration of Conformity............11 UVT-B-AR Version 3.01 - May 2013 Page 3 Operating instructions...
  • Page 4: Safety

    Do not work in the box while the open UV-lamp is switched ON. BIOLOGICAL SAFETY It is the user's responsibility to carry out appropriate decontamination if hazardous material is spilt on or inside the equipment. Version 3.01 - May 2013 UVT-B-AR Page 4 Operating instructions...
  • Page 5: General Information

    UV-recirculator consists of a UV lamp, fan and dust filters organized in a special box, i.e. a person working in the UVT-B-AR is not exposed to UV-radiation and therefore processing the air- flow with UV-light can be performed practically all the time, without interrupting working process.
  • Page 6: Getting Started

    Caution! Due to its size and weight (31.2 kg) the unit requires two people to lift or move it. 3.2. Complete set The unit set includes: Standard set UV-cabinet – DNA/RNA, UVT-B-AR .................1 pce. Spare dust filters.......................2 pcs. Spare fuse (inside the fuse holder) ................1 pce. Power cord ......................1 pce.
  • Page 7: Operation Of Uvt-B-Ar

    4. Operation of UVT-B-AR UV-LIGHT TIME CONTROLLER SETTING TIME (MIN) 0 15 1 VISIBLE LIGHT 2 UV-RECIRCULATOR / UV-LIGHT Start Stop/Reset Fig.1. Control Panel 4.1. Plug the power cord to the grounded mains outlet. Switch ON the Power switch at the rear panel (position I).
  • Page 8 4.3.4. At the end of operation turn OFF switch 2 and switch 1. 4.4. Turn OFF the unit with the Power switch (position O) and disconnect the power plug from the mains outlet. Version 3.01 - May 2013 UVT-B-AR Page 8 Operating instructions...
  • Page 9: Specifications

    1000 W for 230 V and 600 W for 120 V. Optional accessories Description moving table with a drawer and wheel locks, dimensions 800x600x745 mm Grant is committed to a continuous programme of improvement, specifications may be changed without notice. UVT-B-AR Version 3.01 - May 2013 Page 9...
  • Page 10: Guarantee And Service

    To check, replace or clean the filters, simply unclip the covers, if it is necessary fit a new or rinse in water, dry and set up existing filters. Clip covers back in place. Version 3.01 - May 2013 UVT-B-AR Page 10 Operating instructions...
  • Page 11: Declaration Of Conformity

    UVT-B-AR Version 3.01 - May 2013 Page 11 Operating instructions...
  • Page 12 Grant Instruments (Cambridge) Ltd Shepreth Cambridgeshire SG8 6GB Tel: +44 (0) 1763 260811 Fax: +44 (0) 1763 262410 Email: scientificsales@grantinstruments.com www.grantinstruments.com UV-cabinet – DNA/RNA/UVT-B-AR/3.01...