Pelsue PH Series Product Manual

Personnel hoist

Advertisement

Quick Links

Part #501144-001
Product Manual:
PH Series Personnel Hoist
IS O 9 0 0 1 Certified
T.A. Pelsue Company
2500 South Tejon Street
Englewood, Colorado, USA 80110
Tel. 800-525-8460 or 303-936-7432
Fax. 303-934-5581
Internet: www.pelsue.com
Email: sales@pelsue.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PH Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pelsue PH Series

  • Page 1 Part #501144-001 Product Manual: PH Series Personnel Hoist IS O 9 0 0 1 Certified T.A. Pelsue Company 2500 South Tejon Street Englewood, Colorado, USA 80110 Tel. 800-525-8460 or 303-936-7432 Fax. 303-934-5581 Internet: www.pelsue.com Email: sales@pelsue.com...
  • Page 2 Page 2 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 3 Pelsue continues the dedication that industry throughout the world. has made us pre-eminent in this field. Page 3 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 4: Table Of Contents

    6.0........Maintenance & Inspection......21 6.1 ......Maintenance 6.2 ......Inspection 6.3......Hoist Inspection Log 6.4......Hoist Line Inspection Log 7.0........Storage............35 8.0........Contact Information........35 Page 4 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 5: General Information

    EVERY T.A. PELSUE COMPANY EMPLOYEE IS ExPECTED TO COMMIT TO THIS PHILOSOPHY IN THE PERFORMANCE OF HIS OR HER DAILY TASkS. QUALITY FIRST! T.A. PELSUE COMPANY SENIOR MANAGEMENT TEAM Page 5 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 6: Pelsue Product Warranty

    • In the event of failure of any components of a Pelsue product within the warranty period, service must be pre-approved by the T.A. Pelsue Company and service must be performed by the T.A. Pelsue Com- pany Parts and Service Department in Englewood Colorado, or at the option of T.A.
  • Page 7: Introduction & Product Information

    This manual covers the entire line of the PH Series Personnel Hoist manufactured by Pelsue. Use the Table of Contents or Index as a guide to find specific information.
  • Page 8: Configuration & Assembly

    3.0 - Configuration & Components The PH Series Hoist is designed to extend and retract a line from a drum that is used as a tether line when performing a confined space entry operation. The PH Series Hoist is equipped with a long-life friction-brake system that is supplemented by a positive-locking double-pawl arrangement.
  • Page 9 You are responsible for the safe operation, maintenance and inspection of your Pelsue man rated confined space entry/ retrieval system. You must ensure that you and anyone else who is going to operate, maintain, inspect or work around the equipment be familiar with the operating and maintenance procedures and related safety information contained in this manual.
  • Page 10: Warning Statement

    7. Wear appropriate protective gear. This list includes but is not limited to: • A hard hat • Protective shoes with slip resistant soles • Heavy gloves • Protective clothing • Face Protection Page 10 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 11: Operating Safety

    4. Remove the equipment from service if a problem is found during the inspection. Return to an authorized repair depot or the factory for service. Page 11 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 12: Operation

    Section 5.0 will address the basic operation and usage of a Pelsue PH Series Personnel Hoist. Throughout this section and during operation of the PH Series Hoist, the operating safety section of this manual should be constantly referred to and the points address therein should be continually adhered to during all operation. These points have been repeated below.
  • Page 13: Pre-Operation Inspection

    1. General Pelsue PH Series Hoists are designed to be used in work support or rescue applications. It extends and retracts a line as the handle is turned. When the handle is turned, an internal brake holds the drum and the line will not extend or retract.
  • Page 14: System Requirements

    5.4 - System Requirements Pelsue PH Series Personnel Hoists are a component in a confined space entry/retrieval system. The hoist and all auxiliary components must be compatible to prevent creating unexpected hazards. A list of system compatibility requirements includes but is not limited to: 1.
  • Page 15: Field Operation

    5.5 - Field Operation Pelsue PH Series Personnel Hoists are designed for use in many applications including but not limited to personnel riding, rescue or confined space entry/retrieval. It is the responsibility of the operator to be familiar with and follow all applicable OSHA and industry standards on operating guidelines for your project.
  • Page 16 5. Installation/Removal Pelsue PH Series Personnel Hoists are most commonly used on or with a Pelsue Davit System. Normally, the hoist is removed from the davit for storage and transporting. When installing or removing the hoist from the davit, follow this procedure: a.
  • Page 17 PLUNGER Figure 5k: PH Series Hoist Drive Handle Removal Figure 5j: PH Series Hoist Figure 5i: PH Series Hoist Removal Detent Pin Page 17 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 18 Do not enter confined space unless connectors, brakes, hoist and harness are functioning properly. DO NOT TEST OVER CONFINED ENTRY. Page 18 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 19 If the lifeline becomes tight or slack during entry, communicate with the entrant to determine whether there is a problem. Correct the problem before proceeding. ANCHORAGE LIFELINE Page 19 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 20 Inspect and maintain the equipment on a regular basis. Remove defective equipment from service. keep inspec- tion and maintenance records. d. It is recommended that the hoist be used in conjunction with other Pelsue components and systems. These components and systems have the required function, strength and compatibility for all applications. Use them per their instructions.
  • Page 21: Maintenance & Inspection

    The following section will address preventative maintenance points of service, that performed periodically will drastically increase the working life of the PH Series Personnel Hoist. Preventative maintenance will ensure that the PH Series Personnel Hoist is always in optimum working condition.
  • Page 22 Failure to provide proper service may shorten product life and could endanger performance or function. Page 22 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 23: Inspection

    Labels: Check that all the labels are clean and legible. The PH Series Hoist has 3 labels and a serial number decal (see Figures 6c and 6d). Clean the labels if any are dirty using mild soap and a damp cloth. Replace if any are illeg- ible.
  • Page 24 Check the snap hook. Be sure it is not bent, distorted, cracked or worn. Be sure the swivel turns freely and the gate lock and gate open and close easily. Page 24 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 25 See Figure 6h. Do not pull on an end or wire with pliers. It can pull the broken end out to expose it. CORE LENGTH STRAND WIRE ONE REVOLUTION OF A STRAND ABOUT THE CORE Figure 6f Figure 6g Figure 6h Page 25 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 26 IN ONE LAY REDUCED NORMAL DIAMETER DIAMETER ACCESS CONDITION AT SECTION SHOWING MAxIMUM DETERIORATION FLExING CAN REVEAL Figure 6j HIDDEN BREAkS Figure 6i Page 26 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 27 If this is found, remove the unit from service and return to the factory for repair. CRUSHED CABLE Figure 6k: kINkS UNLAYING BENDS Figure 6m BIRD-CAGING Figure 6l Page 27 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 28 Extreme care must be taken under these circumstances and regular rope inspections should take place regularly throughout the day while working to ensure rope integrity. Page 28 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 29: Hoist Inspection Log

    6.3 - Hoist Inspection Log HOIST CHASSIS FUNCTION SNAP HOOK Page 29 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 30: Hoist Line Inspection Log

    IN 1 StrAND eXCeSS BrOKeN IN 1 COrrOSION COrrOSION luBrICAtION lOCAtION* DIAmeter OF 1 lAy WeAr WIre * Note: measure location from snap hook Page 30 501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13...
  • Page 31 At FIttINGS rOPe meASureD eXCeSS KINKS COrrOSION COrrOSION ABrASION HeAt DAmAGe KNOtS lOCAtION* DIAmeter WeAr * Note: measure location from snap hook Page 31 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 32 Notes:...
  • Page 33 Notes:...
  • Page 34 Notes:...
  • Page 35: Storage

    For More Information... t.A. Pelsue Company 2500 S. tejon St. englewood, CO 80110 toll Free: 1-800-525-8460 telephone: 1-303-936-7432 Fax: 1-303-934-5581 Website: www.pelsue.com email: sales@pelsue.com Page 35 501144-001 - Product Manual - PH Series Personnel Hoists - Revison 03 Revision Date - 2018-06-13...
  • Page 36 T.A. Pelsue Company 2500 South Tejon Street, Englewood, Colorado, USA 80110 Toll free 800-525-8460 or 303-936-7432 Fax. 303-934-5581 ISO 9001 Certified Internet: www.pelsue.com Email: sales@pelsue.com...

This manual is also suitable for:

Ph07cPh15rPh20cPh30cPh07rPh10c ... Show all

Table of Contents