Pelsue PHQR Series Product Manual

Quick release man-rated hoist

Advertisement

Quick Links

Part #501272-001
Product Manual:
Model #PHQR Series Quick Release Man-Rated
Hoist
ISO 90 01 C er t if ied
T.A. Pelsue Company
2500 South Tejon Street
Englewood, Colorado, USA 80110
Tel. 800-525-8460 or 303-936-7432
Fax. 303-934-5581
Internet: www.pelsue.com
Email: sales@pelsue.com

Advertisement

Table of Contents
loading

Summary of Contents for Pelsue PHQR Series

  • Page 1 Part #501272-001 Product Manual: Model #PHQR Series Quick Release Man-Rated Hoist ISO 90 01 C er t if ied T.A. Pelsue Company 2500 South Tejon Street Englewood, Colorado, USA 80110 Tel. 800-525-8460 or 303-936-7432 Fax. 303-934-5581 Internet: www.pelsue.com Email: sales@pelsue.com...
  • Page 2 Page 2 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 3 Pelsue continues the dedication that industry throughout the world. has made us pre-eminent in this field. Page 3 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 4: Table Of Contents

    6.0........Maintenance & Inspection......23 6.1 ......Maintenance 6.2 ......Inspection 6.3......Hoist Inspection Log 6.4......Hoist Cable Inspection Log 7.0........Storage............30 8.0........Contact Information........31 Page 4 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 5: General Information

    EVERY T.A. PELSUE COMPANY EMPLOYEE IS ExPECTED TO COMMIT TO THIS PHILOSOPHY IN THE PERFORMANCE OF HIS OR HER DAILY TASkS. QUALITY FIRST! T.A. PELSUE COMPANY SENIOR MANAGEMENT TEAM Page 5 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 6: Pelsue Product Warranty

    • In the event of failure of any components of a Pelsue product within the warranty period, service must be pre-approved by the T.A. Pelsue Company and service must be performed by the T.A. Pelsue Com- pany Parts and Service Department in Englewood Colorado, or at the option of T.A.
  • Page 7: Introduction & Product Information

    This manual covers the entire line of PHQR series hoists manufactured by Pelsue. Use the Table of Contents or Index as a guide to find specific information. Keep this manual handy for frequent reference and to pass to new operators. Establish a regular training program for experienced and new operators per these instructions.
  • Page 8: Configuration & Assembly

    3.0 - Configuration & Components The PHQR series hoist is designed to extend and retract a line from a coiling drum that is to be used as a tether line when performing a confined space entry. Such a tether is required within OSHA and ANSI standards for confined space entry operations The hoist also satisfies the requirement for a emergency retrieval system if and when the need is required.
  • Page 9: Warning Statement

    You are responsible for the safe operation, maintenance and inspection of your Pelsue man rated confined space entry/ retrieval system. You must ensure that you and anyone else who is going to operate, maintain, inspect or work around the equipment be familiar with the operating and maintenance procedures and related safety information contained in this manual.
  • Page 10: Safety Alert Symbol

    Establish a regular maintenance and inspection program with your equipment and maintain detailed records. 10. Review safety related items and operating instructions with all personnel on a regular basis. Page 10 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 11: Operating Safety

    4. Remove the equipment from service if a problem is found during the inspection. Return to an authorized repair depot or the factory for service. Page 11 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 12: Operation

    5.1 - New Operators or Owners The Pelsue PHQR Series confined space entry/retrieval hoist is designed to attach to a person (entrant) and allow them to enter a confined space and assist in exiting in an emergency situation if required. Every new operator must read, understand and follow the instructions in the manual.
  • Page 13: Pre-Operation Inspection

    It is necessary to perform a detailed visual inspection prior to using the hoist. If deficiencies are found, remove the hoist from service and return to the Pelsue factory for repair. This checklist should be used as a guide to determine whether the equipment is in good operating condition prior to usage.
  • Page 14: System Requirements

    1. Anchorage The hoist is designed to be attached to a Pelsue mounting and support system. These systems do provide the required anchorage strength for the hoist. When using another system or anchorage method, anchorage points must meet or exceed the requirements of the applicable standards or local regulations.
  • Page 15 Anchorage We recommend mounting the hoist to other Pelsue supporting components and systems to be sure that the anchorage has sufficient strength. Pelsue support and mounting systems are designed to ANSI and OSHA standards where required. Refer to other product’s owner’s manuals for specific strengths. When using other manufactures’...
  • Page 16 5. Installation/Removal The Pelsue PHQR series man-rated hoists are most commonly used on or with a Pelsue Davit System. Normally, the hoist is removed from the davit for storage and transporting. When installing or removing the hoist from the davit, follow this procedure: a.
  • Page 17 ! CAUTION ! - The rope must be secured in the cleat and wrapped around the drum a minimum of four times before a load can applied to the hoist line! Page 17 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 18 3) Rope should now be wound directed into a neat & level coil on the drum while cranking the handle for “take-up” of the lifeline. Page 18 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 19 Pull the top of the hoist away from the structure and lift the hoist up to unhook it from the anchor rod. See Figure 5g. Store as required. Figure 5g Figure 5f Page 19 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 20 Do not enter the confined space unless connectors, brakes, hoist and harness are functioning properly. DO NOT TEST OVER CONFINED ENTRY. Page 20 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 21 If the lifeline becomes tight or slack during entry, communicate with the entrant to determine whether there is a problem. Correct the problem before proceeding ANCHORAGE LIFELINE Figure 5h Page 21 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 22 Inspect and maintain the equipment on a regular basis. Remove defective equipment from service. Keep inspec- tion and maintenance records. d. It is recommended that the hoist be used in conjunction with other Pelsue components and systems. These components and systems have the required function, strength and compatibility for all applications. Use them per their instructions.
  • Page 23: Maintenance & Inspection

    The following section will address preventative maintenance points of service, that performed periodically will drastically increase the working life of the PHQR Series Man-rated hoist. Preventative maintenance will ensure that the PHQR series man-rated hoist is always in optimum working condition.
  • Page 24 Failure to provide proper service may shorten product life and could endanger performance or function. Page 24 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 25: Inspection

    Labels: Check that all the labels are clean and legible. The PHQR series hoist has 3 labels and a serial number decal. Clean the labels if any are dirty using mild soap and a damp cloth. Replace if any are illegible. Refer to section 2.1 and 3.0 for specific locations of serial number plate and labels.
  • Page 26 Check the snap hook. Be sure it is not bent, distorted, cracked or worn. Be sure the swivel turns freely and the gate lock and gate open and close easily. Page 26 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 27 Extreme care must be taken under these circumstances and regular rope inspections should take place regularly throughout the day while working to ensure rope integrity. Page 27 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 28: Hoist Inspection Log

    6.3 - Hoist Inspection Log FRAME & HOUSING FUNCTION SNAP HOOK Page 28 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 29 DAmAGe At FIttINGS rOPe meASureD CORR- CORROSION eXCeSS WeAr HeAt DAmAGe KNOtS KINKS lOCAtION* DIAmeter OSION ABrASION * Note: Measure location from snap hook Page 29 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 30: Storage

    4. Lubricate the hoist according to the requirements in this manual. 5. Touch up all nicks and scratches in order to prevent corrosion. 6. Store the hoist in a cool, dry place. Page 30 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 31: Contact Information

    For More Information... t.A. Pelsue Company 2500 S. tejon St. englewood, CO 80110 toll Free: 1-800-525-8460 telephone: 1-303-936-7432 Fax: 1-303-934-5581 Website: www.pelsue.com email: sales@pelsue.com Page 31 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
  • Page 32 T.A. Pelsue Company 2500 south tejon street, englewood, colorado, usa 80110 toll free 800-525-8460 or 303-936-7432 fax. 303-934-5581 ISO 9001 Certified Internet: www.pelsue.com Email: sales@pelsue.com...

Table of Contents