Page 1
Part #501272-001 Product Manual: Model #PHQR Series Quick Release Man-Rated Hoist ISO 90 01 C er t if ied T.A. Pelsue Company 2500 South Tejon Street Englewood, Colorado, USA 80110 Tel. 800-525-8460 or 303-936-7432 Fax. 303-934-5581 Internet: www.pelsue.com Email: sales@pelsue.com...
Page 3
Pelsue continues the dedication that industry throughout the world. has made us pre-eminent in this field. Page 3 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
EVERY T.A. PELSUE COMPANY EMPLOYEE IS ExPECTED TO COMMIT TO THIS PHILOSOPHY IN THE PERFORMANCE OF HIS OR HER DAILY TASkS. QUALITY FIRST! T.A. PELSUE COMPANY SENIOR MANAGEMENT TEAM Page 5 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
• In the event of failure of any components of a Pelsue product within the warranty period, service must be pre-approved by the T.A. Pelsue Company and service must be performed by the T.A. Pelsue Com- pany Parts and Service Department in Englewood Colorado, or at the option of T.A.
This manual covers the entire line of PHQR series hoists manufactured by Pelsue. Use the Table of Contents or Index as a guide to find specific information. Keep this manual handy for frequent reference and to pass to new operators. Establish a regular training program for experienced and new operators per these instructions.
3.0 - Configuration & Components The PHQR series hoist is designed to extend and retract a line from a coiling drum that is to be used as a tether line when performing a confined space entry. Such a tether is required within OSHA and ANSI standards for confined space entry operations The hoist also satisfies the requirement for a emergency retrieval system if and when the need is required.
You are responsible for the safe operation, maintenance and inspection of your Pelsue man rated confined space entry/ retrieval system. You must ensure that you and anyone else who is going to operate, maintain, inspect or work around the equipment be familiar with the operating and maintenance procedures and related safety information contained in this manual.
Establish a regular maintenance and inspection program with your equipment and maintain detailed records. 10. Review safety related items and operating instructions with all personnel on a regular basis. Page 10 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
4. Remove the equipment from service if a problem is found during the inspection. Return to an authorized repair depot or the factory for service. Page 11 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
5.1 - New Operators or Owners The Pelsue PHQR Series confined space entry/retrieval hoist is designed to attach to a person (entrant) and allow them to enter a confined space and assist in exiting in an emergency situation if required. Every new operator must read, understand and follow the instructions in the manual.
It is necessary to perform a detailed visual inspection prior to using the hoist. If deficiencies are found, remove the hoist from service and return to the Pelsue factory for repair. This checklist should be used as a guide to determine whether the equipment is in good operating condition prior to usage.
1. Anchorage The hoist is designed to be attached to a Pelsue mounting and support system. These systems do provide the required anchorage strength for the hoist. When using another system or anchorage method, anchorage points must meet or exceed the requirements of the applicable standards or local regulations.
Page 15
Anchorage We recommend mounting the hoist to other Pelsue supporting components and systems to be sure that the anchorage has sufficient strength. Pelsue support and mounting systems are designed to ANSI and OSHA standards where required. Refer to other product’s owner’s manuals for specific strengths. When using other manufactures’...
Page 16
5. Installation/Removal The Pelsue PHQR series man-rated hoists are most commonly used on or with a Pelsue Davit System. Normally, the hoist is removed from the davit for storage and transporting. When installing or removing the hoist from the davit, follow this procedure: a.
Page 17
! CAUTION ! - The rope must be secured in the cleat and wrapped around the drum a minimum of four times before a load can applied to the hoist line! Page 17 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
Page 18
3) Rope should now be wound directed into a neat & level coil on the drum while cranking the handle for “take-up” of the lifeline. Page 18 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
Page 19
Pull the top of the hoist away from the structure and lift the hoist up to unhook it from the anchor rod. See Figure 5g. Store as required. Figure 5g Figure 5f Page 19 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
Page 20
Do not enter the confined space unless connectors, brakes, hoist and harness are functioning properly. DO NOT TEST OVER CONFINED ENTRY. Page 20 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
Page 21
If the lifeline becomes tight or slack during entry, communicate with the entrant to determine whether there is a problem. Correct the problem before proceeding ANCHORAGE LIFELINE Figure 5h Page 21 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
Page 22
Inspect and maintain the equipment on a regular basis. Remove defective equipment from service. Keep inspec- tion and maintenance records. d. It is recommended that the hoist be used in conjunction with other Pelsue components and systems. These components and systems have the required function, strength and compatibility for all applications. Use them per their instructions.
The following section will address preventative maintenance points of service, that performed periodically will drastically increase the working life of the PHQR Series Man-rated hoist. Preventative maintenance will ensure that the PHQR series man-rated hoist is always in optimum working condition.
Page 24
Failure to provide proper service may shorten product life and could endanger performance or function. Page 24 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
Labels: Check that all the labels are clean and legible. The PHQR series hoist has 3 labels and a serial number decal. Clean the labels if any are dirty using mild soap and a damp cloth. Replace if any are illegible. Refer to section 2.1 and 3.0 for specific locations of serial number plate and labels.
Page 26
Check the snap hook. Be sure it is not bent, distorted, cracked or worn. Be sure the swivel turns freely and the gate lock and gate open and close easily. Page 26 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
Page 27
Extreme care must be taken under these circumstances and regular rope inspections should take place regularly throughout the day while working to ensure rope integrity. Page 27 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...
4. Lubricate the hoist according to the requirements in this manual. 5. Touch up all nicks and scratches in order to prevent corrosion. 6. Store the hoist in a cool, dry place. Page 30 #501272-001 - Product Manual: PHQR Series Man-Rated Hoist - Revision 02 - Date: 10-16-2018...