CAME ZBX74-78 Spare Parts page 13

Control board
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
Function selector
F
1 ON - Closing only – with command device connected on contact 2-7 (1 OFF – deactivated)
1 OFF - Open-close – with command device connected on 2-7 (see 10-way Dip Switch 2 of the function selector) (1 ON – deactivated).
2 ON - Only opening – with command device connected on contact 2-3P (2 OFF – deactivated).
2 OFF - Partial opening – with command device connected on contact 2-3P (2 ON – deactivated).
3 ON - Optical reader deactivated; (3 OFF –activated); to program deceleration you need to activated the optical reader.
4 ON - disconnected
NOTE:
make selections when motor is stopped and in the closed position.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.