Download Print this page
Flotec COMPAC 200 Use And Maintenance Manual

Flotec COMPAC 200 Use And Maintenance Manual

Hide thumbs Also See for COMPAC 200:

Advertisement

Quick Links

COMPAC 200
I
ISTRUZIONI ORIGINALI in lingua Italiana
GB
Use and maintenance manual
F
Manuel d'utilisation et d'entretien
D
Bedienungs - und Wartungsanleitung
E
Manual de uso y manutenciòn
P
Manual de utilizição e manutenção
NL
Handleiding voor gebruik en onderhound
DK
Vejledning til brug og vedligeholdelse
FIN
Käittö ja kunnssapito
N
pag. 1
Instruksjonshåndbok og vedlikehold
,,
SE
6
Bruks och underhålls anvisningar
,, 11
GR
EGCEIRLIO CRHEHE KLI EUNTHRHEHE
,, 16
PL
Recyzny uzywaine i obslugi
,, 21
RO
Manual de folosire intretînere
,, 26
H
Hanznàloti utasitàs karbantartàs
,, 31
CZ
Nàvod k pouzitì a k ùdrzbe
,, 36
TR
Kullanma ve bakim el kitabi
,, 41
RUS
pag.46
,, 51
,, 56
,, 61
,, 66
,, 71
,, 76
,, 81
,, 86

Advertisement

loading

Summary of Contents for Flotec COMPAC 200

  • Page 1 COMPAC 200 pag.46 pag. 1 Instruksjonshåndbok og vedlikehold ISTRUZIONI ORIGINALI in lingua Italiana ,, 51 Use and maintenance manual Bruks och underhålls anvisningar ,, 56 ,, 11 Manuel d’utilisation et d’entretien EGCEIRLIO CRHEHE KLI EUNTHRHEHE ,, 61 ,, 16 Bedienungs - und Wartungsanleitung...
  • Page 2 TRANSLATION FROM ORIGINAL INSTRUCTIONS Dear client, Congratulations on your purchase of this FLOTEC product. Like all FLOTEC products, it has been developed with the help of the latest technologies and manufactured with the most advanced electrical/electronic parts. Take the time to read the instructions carefully before using this appliance.
  • Page 3 Sand or other abrasive substances in the pumped fluid will cause the pump to deteriorate and will affect its performances. FLOTEC ComPac electropumps are designed for private use in residential environments and are therefore suited to drain rain water, infiltrated water, to pump water out of flooded areas, and to transfer clean or moderately dirty fluids.
  • Page 4 DANGER this is connected to the mains. FLOTEC ComPac pumps come with a check valve that prevents the delivery pipe from being drained and the fluid from recirculating. If the pump is fixed in a permanent location with rigid pipes, it is advisable to install a quick closing fitting in the most convenient location to facilitate cleaning and maintenance.
  • Page 5 TRANSLATION FROM ORIGINAL INSTRUCTIONS Overload protection FLOTEC ComPac series pumps have a built-in thermal protection switch. The pump stops if an overload condition occurs. The motor restarts automatically after it has cooled down (see chap 7 of the Troubleshooting section for information on causes and corrective actions).
  • Page 6 TRANSLATION FROM ORIGINAL INSTRUCTIONS PROBLEM POSSIBLE CAUSE REMEDY 1) No electricity. 1) THE ELECTROPUMP DOES NOT PUMP WATER, THE MOTOR DOES NOT RUN 2) Plug inserted incorrectly. 2) Verify that voltage is present and that the plug is correctly inserted. 3) Enabled safety switch.