4 Mounting and Installation

4.1
4.2
4.3
Fig. 3: Minimal distances of the sensor to pipe bends and baffles.
5

Delivery Range

Measuring instrument in a 19"-rack system.
Sensor for installation into the pipe.
Seal-ring for adjustment to the pipe.
Operating instructions.

Auxiliary

Appropriate wrench or ring wrench for screwing.
Tools for adjusting the wiring.

Mounting of the Measuring Pipe

The sensor is to be mounted as follows:
Determine the place of mounting on the pipe. On horizontal or inclined pipes the
sensor should be mounted from top.
Follow the necessary distances of valves, bows, fans or cellular wheel sluices etc.
and also other measurement devices like temperature and pressure etc. to the sensor
(see fig. 3).
The mounting has to be in a vertical position.