3. Service menu:
To get into the diagnostic mode press
ESC and ENTER button at the same time
3.1 Display current value A/D-converter 1 (Density)
3.2 Display Voltage level A/D-converter 2 (Velocity)
3.3 Selection Current value for test purposes.
Here a constant current ( 4, 8, 12, 20mA)
can be presetted on output 1 for testing purposes.
Here a constant current ( 4, 8, 12, 20mA)
can be presetted on output 2 for testing purposes.
3.4 Entry of the minimum value for the density range.
usually 0-value (Measuring pipe empty).
The dimensionless value must be changed
so far, until 0% are indicated.
3.5 Entry of the maximum value for the density range.
Here you can enter the value, which can
maximally be expected or a second measuring
point. The dimensionless value must be changed
so far, until the requested percentage is indicated.
3.6 Input of the velocity
Standard = 10m/s ex works presetted.
3.7 DAC-Calibration for current outputs
press ENTER to select submenu
Offset Calibration
for 4 mA output 1 (throughput)
14
Service menu
ADC 1 (Density)
I=0.0mA
[
0h]
ADC 2 (Velocity)
I=0.0mA
[
0h]
DAC Simulation
DAC 1 [ENTER]
I = 04mA
DAC 2 [ENTER]
I = 04mA
Density Min
=
0072 [ 0.0%]
Density Max
=
2568 [ 100%]
Velocity range
=
10.0 m/s
DAC-Calibration
DAC-Calibration
Of's DAC1
+0