Tightening Torques; Lubricants - RMG 672 Operating And Maintenance Instructions/ Spare Parts

Table of Contents

Advertisement

3.3.2 Actuators K10a, K11a/1 and K11a/2 for
RMG 503, RMG 530 and RMG 711 DN 25 thru DN 150
- The shut-off valve must be engaged.
The cap must have been dismounted.
- The switch rod must not rest on the switch bearing.
- The gap must not be greater than 1 mm max.
3.3.3 Actuators K10a, K11a/1 and K11a/2
for RMG 711 DN 200 thru DN 300
- The shut-off valve must be engaged.
The cap must have been dismounted.
- The gap between switching rod and switch
bearing should be 0.3 ± 0.2. If necessary, adjust
by turning the adjusting nut.
Caution
!
3.4
Tightening torques M
Screws and
K10a, K11a/1, K11a/2
bolts - Item no.
21
24
111
122
3.5

Lubricants

Components (cover with thin layer)
Thread of spring plate (4, 101, 114)
Tread of sealing cap (1)
All O rings
Diaphragm support
Slip guides, slip faces and
switching elements
All fastening screws and screwed
pipe connections
3.6 Montage und Einstellwerkzeuge
Tools
Case A19 DIN 5254
Shut-off valve adjusting ke
Screw driver 14 DIN 911
Functional testing
It should not be possible to engage the
actuator after it has been released.
A
Tightening torques M A in Nm
20
65
-
-
K12
-
-
20
20
Lubricant
Assembly paste
Silicone grease
Assembly grease
Part no.
for item no.
26531
10004912
4 and 23
26266
Switching rod
Cap
Cap
Adjusting nut
K13
-
-
20
15
RMG part no.
27091
27081
28267
11
101
Switch bearing
max. 1 mm
Switch bearing
Switch bearing
0,3 ± 0,2
672.20 S. 05

Advertisement

Table of Contents
loading

Table of Contents