Omega OMB-DAQ-54 User Manual page 160

Usb data acquisition modules
Table of Contents

Advertisement

daqSetOption(DaqHandleT handle, DWORD chan, DWORD flags, daqOptionType optionType,
DLL Function
FLOAT optionValue);
C
daqSetOption(DaqHandleT handle, DWORD chan, DWORD flags, DaqOptionType optionType,
FLOAT optionValue);
Visual BASIC
VBdaqSetOption&(ByVal handle&, ByVal chan&, ByVal flags&, ByVal optionType&, ByVal
optionValue!)
daqSetOption(Handle:DaqHandleT; chan:DWORD; flags:DWORD; optionType:daqOptionType;
Delphi
optionValue:FLOAT)
Parameters
handle
chan
flags
optionType
optionValue
DerrNoError
Returns
See Also
daqAdcExpSetChanOption,
PULSEEX1.C, MULTEX1.C, FREQEX1.C, DAQEX.FRM (VB), DAQEX.PAS (Delphi)
Program References
All devices
Used With
Description
daqSetOption allows the setting of options for a device's channel/signal path configuration.
chan specifies which channel the option applies to.
flags parameter specifies how the option is to be applied.
optionType specifies the type of option to apply to the channel.
optionValue parameter specifies the value of the option.
Note: For more information regarding optionValue and optionType refer to page B-32, Table 8.
Note: The following information does not apply to Personal Daq/54.
daqSetOption must be used to properly configure Personal Daq's frequency input and pulse count channels. To configure frequency input
and pulse count channels, the following option types need to be specified for each frequency input/pulse count channel in the scan
sequence:
DcotpDaqPulses: Configures the specified channel as a pulse count channel.
DcotpDaqRising: Configures the rising flag for the pulse channel.
DcotpDaqDebounceTime: Configures the debounce time for the frequency/pulse channel.
The following options must also be specified to configure frequency input channels:
DcotpDaqMinFreq: Configures the minimum frequency range for the specified channel.
DcotpDaqMaxFreq: Configures the maximum frequency range for the specified channel.
DcotpDaqFreqRes: Configures the resolution of the specified frequency channel.
DcotpDaqOverrangeProtect: Enables the overrange protection mode.
daqSetTimeout(DaqHandleT handle, DWORD mSecTimeout);
DLL Function
daqSetTimeout(DaqHandleT handle, DWORD mSecTimeout);
C
Visual BASIC
VBdaqSetTimeout&(ByVal handle&, ByVal mSecTimeout&)
daqSetTimeout(handle:DaqHandleT; mSecTimeout:DWORD)
Delphi
handle
Parameters
mSecTimeout
Returns
DerrNoError
daqWaitForEvent, daqWaitForEvents
See Also
None
Program References
Used With
All devices
Description
daqSetTimeout allows you to set the time-out for waiting on a single event or multiple events. This function can be used in conjunction
with the daqWaitForEvent and daqWaitForEvents functions to specify a maximum amount of time to wait for the event(s) to be
satisfied.
The mSecTimeout parameter specifies the maximum amount of time (in milliseconds) to wait for the event(s) to occur. If the event(s) do
not occur within the specified time-out, the daqWaitForEvent and/or daqWaitForEvents will return.
Personal Daq User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
daqSetOption
The handle to the device for which to set the option
The channel number on the device for which the option is to be set
Flags specifying the options to use.
Specifies the type of option.
The value of the option to set
No error
daqSetTimeout
Handle to the device for which the event time-out is to be set
Specifies time-out ( ms ) for events
No error
Appendix B,
887095
API Commands
B-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omb-daq-55Omb-daq-56