daqAdcSetMux(DaqHandleT handle, DWORD startChan, DWORD endChan, daqAdcGain gain,
DWORD flags);
daqAdcSetMux(DaqHandleT handle, DWORD startChan, DWORD endChan, DaqAdcGain gain,
C
DWORD flags);
Visual BASIC
VbdaqAdcSetMux&(ByVal handle&, ByVal startChan&, ByVal endChan&, ByVal gain&, ByVal
flags&)
Delphi
daqAdcSetMux(handle:DaqHandleT; startChan:DWORD; endChan:DWORD; const
gain:daqAdcGain; flags:DWORD)
Parameters
Handle
StartChan
EndChan
Gain
Flags
DerrInvGain
Returns
DerrIncChan
DerrNoError
daqAdcSetScan, daqAdcGetScan
See Also
Program References
None
Used With
All devices
Description
daqAdcSetMux sets a simple scan sequence of local A/D channels from startChan to endChan with the specified gain value. This
command provides a simple alternative to daqAdcSetScan if only consecutive channels need to be acquired. The flags parameter is
used to set channel dependent options. See ADC Flags Definition table for channel flags definitions.
daqAdcSetRate(DaqHandleT handle, daqAdcRateMode mode, daqAdcAcqState acqState, FLOAT
DLL Function
reqRate, PFLOAT actualRate);
C
daqAdcSetRate(DaqHandleT handle, DaqAdcRateMode mode, DaqAdcAcqState acqState, FLOAT
reqRate, PFLOAT actualRate);
Visual BASIC
VBdaqAdcSetRate(ByVal handle&, ByVal mode&, ByVal acqState&, ByVal reqRate!,
actualRate!);
daqAdcSetRate(handle:DaqHandleT; mode:daqAdcRateMode; state:daqAdcAcqState;
Delphi
handle
Parameters
mode
acqState
reqRate
actualRate
DerrNoError
Returns
daqAdcSetAcq, daqAdcSetTrig, daqAdcArm, daqAdcSetFreq, daqAdcGetFreq
See Also
Program References
DAQEX.PAS (Delphi), ADCEX1.C, FREQEX1.C, PULSEEX1.C, MULTEX1.C, DAQEX.FRM (VB)
All devices
Used With
Description
daqAdcSetRate configures the scan rate using the rate mode specified by the mode parameter. Currently, the valid modes are:
DarmPeriod - Defines the requested rate to be in periods/sec.
DarmFrequency - Defines the requested rate to be a frequency. This function will set the acquisition rate requested by the
reqRate parameter for the acquisition state specified by the acqState parameter.
Currently, the following acquisition states are valid:
DaasPreTrig - Sets the pre-trigger acquisition rate to the requested rate.
DaasPostTrig - Sets the post-trigger acquisition rate to the requested rate.
Personal Daq does not allow a pre-trigger rate different from the post-trigger rate. Therefore, the pre-trigger rate settings will be ignored
and the post-trigger rate will be used for both the pre-trigger and the post-trigger scan rates.
If the requested rate is unattainable on the specified device, a rate will be automatically adjusted to the device's closest attainable rate. If
this occurs, the actualRate parameter will return the actual rate for which the device has been programmed.
B-12
API Commands
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
daqAdcSetMux
Handle to the device for which to configure the ADC channel scan group
The starting channel of the scan group
The ending channel of the scan group
The gain value for all channels
Channel configuration flags in the form of a bit mask
Invalid gain
Invalid channel
No error
daqAdcSetRate
reqValue:single; actualValue:PSINGLE);
Handle to the device for which to set ADC scanning frequency.
Specifies the rate mode (frequency or period).
Specifies the acquisition state to which the rate is to be applied.
Specifies the requested rate.
Returns the actual rate applied. This may be different from the requested rate.
No error
Appendix B,
887095