Table B-1. Functionality Differences Between the PC-LPM-16 and the DAQCard-700
Functionality
FIFO read
FIFO buffer size
Maximum sample rate
Supply voltages at I/O connector
Maximum input voltage rating
ADC calibration
Timer chip
Maximum timer source frequency
Input modes
Input ranges
* The MSM82C54 timer used in the DAQCard-700 is compatible with the MSM82C53.
© National Instruments Corporation
This appendix contains a summary of differences between the PC-LPM-16
and the DAQCard-700 that may be relevant to you if you are a current
PC-LPM-16 user.
The DAQCard-700 is compatible with the PC-LPM-16. Software
developed for the PC-LPM-16 using NI-DAQ or LabWindows routines,
as well as LabVIEW VIs for the PC-LPM-16, typically works with the
DAQCard-700 without modification. The following table summarizes
the significant differences.
PC-LPM-16
Two 8-bit words
16 samples
50 kS/s
+5 V, +12 V, –12 V
± 45 V
Hardware calibration
MSM82C53
8 MHz
Single ended
±5 V, ±2.5 V, 0–10 V, 0–5 V,
jumper selectable
One 16-bit word
512 samples
100 kS/s
+5 V
± 30 V
Software calibration
MSM82C54*
10 MHz
Single ended or differential
±10 V, ±5 V, ±2.5 V,
software-selectable