Ccd b/w camera module
Hide thumbs Also See for XC-ES50/50CE:
Table of Contents

Advertisement

XC-E series
ELECTRONIC SHUTTER
When using a trigger pulse like shown below, set the TRIG polarity selector switch on the rear panel to – :
A: 4.0 to 5.0 V
B:
0 to 2.0 V
T: 2 s to 1/4 s, 100 s to 1/4 s when setting the shutter speed using DIP switch
Input impedance: 10 k or more
*
The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.
*
Specifications of WEN (Write ENable Pulse)
Output impedance: 10 k or more
*
10
T
T
A: 5.0 V
B: 0 V
T: 15.875 ms (XC-ST70), 18.752 ms (XC-ST70CE)
A
B
A
B