5. Set Background Gas Level
To access to this feature press TEST once then MENU once "brd" will flash on the display when in that
mode. (Default setting is 7) Use the Up and Down buttons to adjust the Background level.
When the gas level is equal to or greater than this number, the unit will transmit a message every 5
seconds; if less
than this setting, the unit transmit every 5 minutes..
6. Check Battery Voltage
This mode displays the condition of the batteries. To access to this feature press TEST once then MENU
twice "bat" will flash on the display when in this mode.
7. Select Redline message or 784 message
(This mode is new to revisions 2.0 or greater). If the RL101 sensor head is in the wrong setting of 784,
use the up or down buttons to change back to "Red".
** if the RL101 sensor head is in 784 it will not communicate to the Redline Monitor**
.
8. Revision
This mode shows the revision of the software that is being used in the RL101 Head unit. To access press
TEST Twice.

9. Relay Test

To place the RL101 sensor Head in relay test mode press the TEST button twice and the MENU button
once "REL" will show on the display. Use the Up and Down buttons to adjust the PPM value to send in a
message to the Monitor.
The Monitor treats this PPM value in the same way it would treat an actual gas reading.
This will allow for the relays in the Monitor to be activated and shows that the Head unit
is communicating with the Monitor.