SETTINGS OF CAMERA CONTROL AND STATUS REGISTER
CSR F100000Ch
Image Size
Set the size of the area when cutting one part of the screen by the partial scan function.
Minimum Unit for DFW-SX900
Set the size of the area using the width and height of the rectangular area composed of the minimum units in the above
figure.
<When DFW-SX900>
Command = 0iii0jjjh
Width (x)
---------------------------------------------------------
1/4 of whole screen
1/2 of whole screen
3/4 of whole screen
Whole screen
<When DFW-X700>
Command = 0iii0jjjh
Width (x)
---------------------------------------------------------
1/2 of whole screen
Whole screen
30
0
1/2
1/2
y
iii: Width of area
i i i
140h (320)
280h (640)
3C0h (960)
500h (1,280)
iii: Width of area
i i i
200h (512)
400h (1,024)
Minimum Unit for DFW-X700
x
This area is 1/4 the width and 1/2 the height
of the whole screen.
jjj: Height of area
Height (y)
--------------------------------------------------------
1/4 of whole screen
1/2 of whole screen
3/4 of whole screen
Whole screen
jjj: Height of area
Height (y)
--------------------------------------------------------
1/4 of whole screen
1/2 of whole screen
3/4 of whole screen
Whole screen
j j j
0F0h (240)
1E0h (480)
2D0h (720)
3C0h (960)
j j j
0C0h (192)
180h (384)
240h (576)