Product Specifi Ca Ons - Gallagher MBS100 Instructions Manual

Multi-power fence energizer
Hide thumbs Also See for MBS100:
Table of Contents

Advertisement

3E4723 Gallagher MBS100 MBS200 MBS400 MBS800 Mul -Power User Manual
Symptom
Problem
Short on the fence
line
PRODUCT SPECIFICATIONS
Ba ery Type
Ba ery Performance
Peak Current
Average Current
Output Voltage
(no load)
Stored Energy
Output Energy
Dimensions: HxWxD
Weight
IP Ra ng
Mains Adaptor
*based on a fully charged 100 Ah ba ery.
**MBS100 Not available in Europe or North America.
Solu on
Check the voltage on the fence every 33m
(100 ) using Gallagher Fault Finder. The closer
to a fault, the lower the voltage reading will
be. Become aware of things that cause faults
and always be on the lookout for: stray pieces
of wire on the fence, heavy vegeta on growth,
cracked or broken insulators, broken wires.
MBS100**
MBS200
12 V
18 days*
12 days*
285 mA
310 mA
118 mA
176 mA
8.1 kV
9.0 kV
1.25 J
0.97 J
221mm x 203mm x 107mm
1.31 kg
Input: 110-240 Vac, Output 15 V 0.8A, 12W
Europe - G40121, North America - G40123, AUS/NZ - G40125
MBS400
12 V
12 V
9 days*
900 mA
195 mA
9.1 kV
2J
4J
1.5 J
3.0 J
280mm x 260mm x 140mm
2.6 kg
IPX4
MBS800
12 V
5 days*
1000 mA
331 mA
9.2 kV
8 J
(USA, NZ, AUS)
7.55 J
(Europe)
5.9 J
(USA, NZ, AUS)
4.7 J
(Europe)
2.9 kg
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mbs400Mbs200Mbs800