Advertisement

INSTALLATION OPERATIONS AND MAINTENANCE
HTX-HTH SEPARATORS I&O MANUAL
1365 N. Clovis Avenue
Fresno, California 93727
(559) 255-1601
www.lakos.com
LS-714B (Rev. 11/17)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HTX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lakos HTX Series

  • Page 1 INSTALLATION OPERATIONS AND MAINTENANCE HTX-HTH SEPARATORS I&O MANUAL 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com LS-714B (Rev. 11/17)
  • Page 2: Table Of Contents

    Installation Operations and Maintanence TABLE OF CONTENTS Table of Contents ................Page 2 Principle of Operation ................. Page 3 Operation/Installation ..............Page 3-4 Recommended Piping ................ Page 4 Maintenance Purging ................. Page 5 Maintenance Recommendations ............Page 6 Trouble-Shooting ................Page 7-9 HTH Flow vs Pressure Loss Chart ............
  • Page 3: Principle Of Operation

    Installation Instructions 1. LAKOS Separators are shipped on skids or in wooden crates. Support legs (22 ½° low profiles only) are detached. Lifting Lugs, located on the unit’s side and/or flanges, are provided for hoisting as necessary.
  • Page 4: Recommended Piping

    Grooved couplings are not included with the separator. Optional flanged connections are available upon request. 7. Inlet pressure to the LAKOS Separator must be at least equal to or greater than the anticipated pressure loss through the separator plus 15 psi (1 bar) plus whatever downstream pressure is required.
  • Page 5: Maintenance Purging

    Once the bag is full with solids, the bag is emptied. The bag can be cleaned and reused, or simply replaced. Consult your LAKOS representative for details on the solids recovery vessel and accessories.
  • Page 6: Maintenance Recommendations

    Installation Operations and Maintanence Maintenance Recommendations LAKOS recommends periodic inspections of the separator to keep performance at an optimum level. Full Faced Flange Gasket or Victaulic Gaskets should be checked for leaks and replaced as necessary. Gasket should be replaced at disassembly of separator.
  • Page 7 Installation Operations and Maintanence Trouble-Shooting Guidelines For Separator Installation 1. Verify Actual Flow Rate: Use pressure gauges to indicate differential pressure and flow meter to verify flow rate. (Multiple pumps used to increase flow are installed in parallel (into common manifold); multiple pumps to increase pressure are installed in series (one after another).
  • Page 8: Trouble-Shooting

    The use of expansion joints is advisable with all separator installations. It is particularly recommended that these devices be employed when piping arrangements cannot comply with the configurations suggested by LAKOS product literature. 5. Vertical Units: Be aware that solids may accumulate within the separator for a period of time until the solids reach the level of the purge outlet.
  • Page 9 Installation Operations and Maintanence Trouble-Shooting Guidelines For Separator Installation (continued) 8. Installation: Proper installation should always include an isolation valve between the separator purge outlet and any purge system. This will allow for the easy removal of the purge system for servicing without having to shut down the entire system.
  • Page 10: Hth Flow Vs Pressure Loss Chart

    Installation Operations and Maintanence HTH Flow vs Pressure Loss Chart HTH-0285 Flow Rate (m /hr) HTH-0450 1,0002 ,000 HTH-0500 HTH-0810 HTH-1275 HTH-1950 HTH-3500 HTH-6700 2003 1,000 2,000 5,000 10,000 Flow Rate (U.S. gpm) HTX Flow vs Pressure Loss Chart HTX-0016 Flow Rate (m /hr) HTX-0028...
  • Page 11: Spare Parts

    Installation Operations and Maintanence HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0004 PART DESC Description 2 Description 3 Description 4 118504 GROMMET STRIP 15/16” x 1/4” EPDM / 6” LG 106140 GASKET COUPLING 3 TYPE E GROOVE EPDM *118512 GAUGE, 160PSI CARBON STEEL...
  • Page 12 Installation Operations and Maintanence HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0038 PART DESC Description 2 Description 3 Description 4 118504 GROMMET STRIP 15/16” x 1/4” EPDM / 11 7/8” LG 106142 GASKET COUPLING 6 TYPE E GROOVE EPDM *118512 GAUGE, 160PSI...
  • Page 13 Installation Operations and Maintanence HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0130 PART DESC Description 2 Description 3 Description 4 118504 GROMMET STRIP 15/16” x 1/4” EPDM / 20” LG 106140 GASKET COUPLING 8 TYPE E GROOVE EPDM *118512 GAUGE, 160PSI CARBON STEEL...
  • Page 14 Installation Operations and Maintanence HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0450 PART DESC Description 2 Description 3 Description 4 118504 GROMMET STRIP 15/16” x 1/4” EPDM / 33 3/8” LG 116634 GASKET COUPLING 14 TYPE E GROOVE EPDM *106205 GASKET...
  • Page 15 Installation Operations and Maintanence HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-1275 PART DESC Description 2 Description 3 Description 4 118504 GROMMET STRIP 15/16” x 1/4” EPDM / 55 3/4” LG 121285 GASKET COUPLING 24 TYPE E GROOVE EPDM *106205 GASKET...
  • Page 16: Spare Parts

    Installation Operations and Maintanence HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-3500 PART DESC Description 2 Description 3 Description 4 119702 GASKET ANSI 16” HTX 36 150# 1/8 THK NEOPRENE *106205 GASKET HANDHOLE 4” x 6” NEOPRENE *118512 GAUGE, 160PSI CARBON STEEL 160 PSI, 1/4 MNPT...
  • Page 17: Notes

    Installation Operations and Maintanence NOTES: Separator Model:____________________________________ Sales Order #:_______________________________________ Purchase Date:______________________________________ Distributor:_________________________________________ System Flow:_____________________ Separator Delta P:_________________ 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com...