Safety Information; Important Safety Instructions - Caldera Makena Owner's Manual

Table of Contents

Advertisement

S
I
afety
nformatIon
IMPORTANT SAFETY
INSTRUCTIONS
(READ AND FOLLOW ALL
INSTRUCTIONS)
AVOIDING THE RISK TO CHILDREN
DANGER - RISK OF CHILD DROWNING
Extreme caution must be exercised to prevent unauthorized access
by children. To avoid accidents, ensure that children cannot use a spa
unless they are supervised at all times.
WARNING
To reduce the risk of injury, do not permit children to use this spa unless
they are closely supervised at all times.
• To reduce the risk of injury, do not permit children to use this spa
unless they are closely supervised at all times.
• To reduce the risk of injury, lower water temperatures are
recommended for young children. Children are especially sensitive to
hot water.
• The device should not be used by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they receive supervision or training.
DO:
• Make sure you always lock the child resistant locks after using the
spa for your children's safety. Every CALDERA spa is equipped with
a locking cover that meets the ASTM F1346-91 Standard for Safety
Covers.
• Test the water temperature with your hand before allowing children to
enter the spa to be sure that it's comfortable. Children are especially
sensitive to hot water.
• Remind children that wet surfaces can be very slippery. Make sure
that children are careful when entering or exiting the spa.
DON'T:
• Allow children to climb onto the spa cover.
• Allow children to have unsupervised access to the spa.
AVOIDING THE RISK OF ELECTROCUTION
DANGER - RISK OF ELECTROCUTION
• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death,
or serious personal injury due to electrocution if direct burial-type
cable is not used, or if improper digging occurs.
• A ground terminal (pressure wire connector) is provided on the
control box inside the unit to permit connection of a minimum
10 mm² solid copper bonding conductor between this point and any
metal equipment, metal water pipe, metal enclosures of electrical

Safety Information

equipment, or conduit within 1.5 m (5') of the unit as needed to
comply with local requirements.
• Do not operate the main audio/video button controls on any external
media devices such as a CD or DVD player while inside in the spa.
Operation of integrated audio/video equipment through the spa
control panel or wireless remote is permitted and acceptable.
• Do not connect any auxiliary components (for example, cable
additional speakers, headphones, additional audio components) to
the audio system unless approved by Watkins Wellness .
• Do not self service audio component by opening spa door as this
may expose dangerous voltage or other risk of injury. Refer all
servicing to qualified service personnel.
• Do not attach an external antennae to a spa audio system unless
installed by a licensed electrician in accordance with National Electric
Code.
WARNING
• To reduce the risk of electrical shock, replace a damaged cord
immediately. Failure to do so may result in death or serious personal
injury due to electrocution.
• In order to avoid a hazard due to inadvertent resetting of the thermal
cut-out, this appliance must not be supplied through an external
switching device, such as a timer, or connected to a circuit that is
regularly switched on and off by the utility.
• Always test the residual current device (RCD) before each use of the
spa. If the RCD does not perform properly, a ground current is flowing
indication the possibility of electric shock. Disconnect power to the spa
until the fault has been identified and corrected.
• NOTE: Failure to wait 30 seconds before resetting the RCD may
cause the spa's Power Indicator (on the control panel) to blink. If this
occurs, repeat the RCD test procedure.
• Your spa must be supplied by a residual current device with a tripping
rating not exceeding 30 mA in an electrical subpanel.
DANGER - RISK OF ELECTRICAL SHOCK
• Install spa at least 1.5 m (5') from all metal surfaces. A spa may be
installed within 1.5 m (5') of a metal surface if each metal surface is
permanently connected by a minimum 10 mm
attached to the wire ground connector on the terminal box that is
provided for this purpose.
• Do not permit any electrical appliances, such as a light, telephone,
radio, or television within 1.5 m (5') of a spa. Failure to maintain a
safe distance may result in death, or serious personal injury due to
electrocution, if the appliance should fall into the spa.
• Install your spa in such a way that drainage is away from the electrical
compartment and from all electrical components.
DO:
• Be sure your spa is connected to the power supply correctly - use a
licensed electrical contractor.
• Disconnect the spa from the power supply before draining the spa or
servicing the electrical components.
• Test the Ground Fault Circuit Interrupter(s) before each use.
• Replace audio components only with identical components (if your spa
is equipped with an audio component).