display application manages the continuous display of operating parameters, status, alarm, or unusual
conditions on the LCD. Displayed parameters and other indicators help operators obtain quick visual
information on the status and health of the system. Displayed values scroll in the LCD at
programmable time intervals and duration.
You can customize the basic factory default LCD configuration. For example:
 Change the default parameter display time of 5 seconds (value range: 1 to 255 seconds)
 Add/define additional applications and their parameters for additional monitoring
 Activate additional annunciators or alarm indicators and assign to desired applications
IMPORTANT NOTE: PCCU provides online help topics for the Display application. Click Help from
any of the display application screens for configuration information.
For default parameters, see the table below. For default annunciators, see section
and status codes.
Table 1-5: Default display parameters
Standard display
Station information
STATION ID
DATE/TIME
CHARGER
BATTERY VOLTAGE
LITHIUM BACK-UP?
Measurement tube identification and information
TUBE # ID
TUBE # ORIFICE DIAMETER N.NNN INCHES
TUBE # SP
TUBE # DP
TUBE # TEMPERATURE
TUBE # FLOW RATE
TUBE # LAST CALC.
TUBE # YEST. VOL.
TUBE # ACCUM. VOL.
1.2.8

Configuration files

The configuration files contain application and parameter settings which define how the device
operates. The XSeries
1 8 | XSE RI ES G5 | 2 10 6 02 6MNAA
Format
XXXXXXXXXXXXXXXXX
MM/DD/YY
HH:MM: SS
NNNNNNNN.N Volts
NNNNNNNN.N Volts
[Yes or No]
XXXXXXXXXXXXXXXXX
NNN.N PSIA
NNN.N IN. H2O
NN. N DEG F
NNNNNN.N SCF/HR
NNNNNNNN.N SCF
NNNN.N MCF
NNNNNN.NN MCF
G5
device contains the following configuration files:
12.1 LCD visual alarm
Description
ID of the unit
Current date and time, 24-hour clock
Input voltage of the charging unit
Battery voltage as supplied by the external
unit
Lithium battery used as backup
ID of the tube
Size of the orifice plate
Static pressure absolute, PSIA
Differential pressure, inches H2O
Flowing temperature, °F
Current flow rate, programmable SCF, MCF
or MMCF per hour
Last calculated volume
Yesterday's volume, programmable SCF,
MCF or MMCF
Total accumulated volume, programmable
SCF, MCF or MMCF