Bosch DM**8001 Series Parameter And Commissioning Manual page 70

Frequency inverters (asm)
Table of Contents

Advertisement

Displays on the Module
8–2
Read
Unit
from
DSS
A09
A-0-1009
%
A10
A-0-1010
_C
A11
A-0-1011
A
A12
A-0-1012
A13
A-0-1013
A14
A-0-1014
A15
A-0-1015
Description
Utilization
Heat sink temperature
Present current limit
TEMP warning
U00
U01
U02
U03
Last fault after
STA deactivation
Software version
Software index
Current utilization of the motor,
for f < f
with respect to the motor torque M
N
for f > f
with respect to the motor power P
N
Accuracy:
depending on the motor,
for n > 0.1 n
N
Current heat sink temperature.
With increased heat sink temperature: Warning 'U01', TEMP
relay is opened.
The currently active current limit is adjusted depending on
the selected settings and the current heat sink temperature.
WARNING after deactivation of TEMP relay:
no warning
heat sink temperature too high
motor temperature too high.
Only if bimetal function P43–P45 is active.
heat sink and motor temperature too high.
After restart, the last error present before STA was deacti-
vated is displayed.
Number left of point = software status
Number right of point = software scope.
Please quote in all communication.
Index of operating software release,
please quote in all communication.
N
N
approx. 5% of the final value
1070 066 028-101 (01.05) GB

Hide quick links:

Advertisement

Table of Contents
loading