Before installation

Read through the following instructions before installing the dryer, and keep this manual
for future reference.
WARNING
Certain internal parts are intentionally not grounded and may present a risk of electric
shock only during servicing. Service Personnel - Do not contact the following parts while
the appliance is energized: Control board, Motor, Drain pump.

Key installation requirements

• A grounded electrical outlet.
• A power cord for electric dryers (except
in Canada).
• An exhaust system made of rigid metal
or flexible stiff-walled metal exhaust
ducting.

Location considerations

• Adequate clearances between the dryer
and adjacent walls or other surfaces.
• Adequate air circulation for ventilation.
• Away from water and weather.
WARNING
• Make sure to exhaust the dryer
outdoors to reduce the risk of fire.
• Keep the dryer area clear of
combustible materials, gasoline, and
other flammable vapors and liquids.
• Do not install other fuel-burning
appliances around or in the same place
as the dryer.
• Place dryer at least 18 in (460mm)
above the floor for a garage installation.
DV6850N_DC68-03650E-00_EN.indd 9
WARNING
Remove the door from all discarded
appliances to prevent a child from
suffocating.
Alcove or closet installation
Minimum clearances between the dryer
and adjacent walls or other surfaces are:
3" (76mm) in front, 1" (25 mm) on top,
1"(25mm) on either side, and 2'' (50 mm)
in the back.
The closet front must have two
unobstructed air openings for a combined
minimum total area of 72 in² (465 cm²)
with 3" (7.6 cm) minimum clearance on
the top and bottom. A louvered door with
equivalent space clearance is acceptable.